CS Instrument Vietnam, Danh Sách Sản PhẩmCS Instrument Vietnam
CHART RECORDER -- Cảm biến khí gas có hiển thị | ||||||
4-13 | Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation | DS 500 + Accessories | CS-instrument/CSInstrument/CS Instrument | |||
14-25 | Intelligent mobile chart recorder Energy analysis - consumption measurement - leakage calculation at compressed air systems |
DS 500 mobile + Accessories |
CS-instrument/CSInstrument/CS Instrument | |||
18-25 | Affordable mobile chart recorder, Energy analysis - flow measurement - leckage calculation at compressed air systems | DS 400 mobile | CS-instrument/CSInstrument/CS Instrument | |||
26 | Mobile current/effective power meter suitable for DS 500/ DS 400 mobile | CS PM 600 | CS-instrument/CSInstrument/CS Instrument | |||
27 | CS ENERIUM 30 Current/effective power meter for panel mounting |
CS ENERIUM 30 | CS-instrument/CSInstrument/CS Instrument | |||
28-34 | Hand-held instrument e.g. for flow measurement | PI 500 | CS-instrument/CSInstrument/CS Instrument | |||
HUMIDITY/DEW POINT MEASUREMENT - cảm biến độ ẩm/ điểm sương | CS-instrument/CSInstrument/CS Instrument | |||||
40-45 | Portable dew point meter for relative humidity, temperature, dew point measurement |
DP 500 / DP 510 | CS-instrument/CSInstrument/CS Instrument | |||
46-47 | Portable dew point meter with integrated pressure sensor | DP 400 mobile | CS-instrument/CSInstrument/CS Instrument | |||
50-51 | Dew point sensor for membrane and desiccant driers | FA 510/515 DS 52-Set |
CS-instrument/CSInstrument/CS Instrument | |||
52-53 | Dew point sensor for refrigeration driers | FA 510/515 DS 52-Set |
CS-instrument/CSInstrument/CS Instrument | |||
54-59 | Dew point set for compressed air and gases | DS 400 | CS-instrument/CSInstrument/CS Instrument | |||
60-61 | Dew point measurement for refrigeration, membrane and desiccant dryers |
FA 500 | CS-instrument/CSInstrument/CS Instrument | |||
62 | Dew point measurement in explosive areas | FA 515 Ex | CS-instrument/CSInstrument/CS Instrument | |||
62 | Accessories mains units | CS-instrument/CSInstrument/CS Instrument | ||||
63-64 | Accessories for dew point measurement and calibration | CS-instrument/CSInstrument/CS Instrument | ||||
FLOW/CONSUMPTION MEASUREMENT - Máy đo lưu lượng khí/ gas | CS-instrument/CSInstrument/CS Instrument | |||||
69-80 | Precise flow measurement for compressed air and gases for heavy duty industrial applications |
VA 550/570 (ATEX) | CS-instrument/CSInstrument/CS Instrument | |||
81-89 | Flow sensors for compressed air and gases | VA 500/520 | CS-instrument/CSInstrument/CS Instrument | |||
90-97 | Flow station for compressed air and gases | DS 400 | CS-instrument/CSInstrument/CS Instrument | |||
98-99 | Flow direction switch for compressed air systems | VA 409 | CS-instrument/CSInstrument/CS Instrument | |||
100 | Useful accessories: Measuring sections, Drilling jig | CS-instrument/CSInstrument/CS Instrument | ||||
101 | Useful accessories: Spot drilling collars, thickness meter | CS-instrument/CSInstrument/CS Instrument | ||||
103 | Calibration of flow sensors | CS-instrument/CSInstrument/CS Instrument | ||||
Cata- log- ue page |
Description | Device | ||||
Compressed air quality according to ISO 8573 - Cảm biến đo lường khí nén theo tiêu chuẩn ISO | ||||||
108-113 | Compressed air quality measurement according to ISO 8573 |
OIL-Check/PC 400 | CS-instrument/CSInstrument/CS Instrument | |||
LEAKAGE MEASUREMENT - Cảm biến đo rò rỉ khí | ||||||
114-117 | Leak detector with camera | LD 500 / 510 | CS-instrument/CSInstrument/CS Instrument | |||
118-119 | Leak detector for compressed air systems | LD 400 | CS-instrument/CSInstrument/CS Instrument | |||
PRESSURE MEASUREMENT - Cảm biến đo áp suất | ||||||
120-121 | Differential Pressure Sensor 1.6 bar diff | Differential pressure sensor |
CS-instrument/CSInstrument/CS Instrument | |||
DIGITAL DISPLAYS - Cảm biến hiển thị số (dạng gắn cố định) | ||||||
122-123 | Digital displays for wall or panel mounting | DS51 / DS52 | CS-instrument/CSInstrument/CS Instrument | |||
Calibration - Dịch vụ hiệu chuẩn | ||||||
64 | Calibration services for dew point, relative humidity | CS-instrument/CSInstrument/CS Instrument | ||||
103 | Calibration services for flow sensors | CS-instrument/CSInstrument/CS Instrument | ||||
Re-calibration and service | CS-instrument/CSInstrument/CS Instrument | |||||
Products not included in the catalogue: sản phẩm không nằm trong danh mục catalogue | CS-instrument/CSInstrument/CS Instrument | |||||
FA 540 dew point sensor with same pinning at M12 plugas FA 410 | FA 540 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 545 dew point sensor with same pinning at M12 plugas FA 415 | FA 545 | CS-instrument/CSInstrument/CS Instrument | ||||
Terms & Conditions | CS-instrument/CSInstrument/CS Instrument | |||||
DS 500 - Intelligent chart recorder - Bộ hiển thị & lưu trữ dữ liệu | ||||||
Catalogue page 8 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
DS 500 - intelligent chart recorder in basic version (4 sensor inputs) | 0500 5000 | CS-instrument/CSInstrument/CS Instrument | ||||
Option 4 additional sensor inputs for DS 500 | Z500 5001 | CS-instrument/CSInstrument/CS Instrument | ||||
Option 8 additional sensor inputs for DS 500 | Z500 5002 | CS-instrument/CSInstrument/CS Instrument | ||||
Option Integrated webserver | Z500 5003 | CS-instrument/CSInstrument/CS Instrument | ||||
Option "consumption report" statistics, daily/weekly/monthly report | Z500 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Option version for panel mounting | Z500 5006 | CS-instrument/CSInstrument/CS Instrument | ||||
Option power supply 24VDC (instead of 100...240 VAC) | Z500 5007 | CS-instrument/CSInstrument/CS Instrument | ||||
Option “mathematics calculat. function” for 4 freely selectable “virtual” channels, (mathematical functions: addition, subtraction, division, multiplication) |
Z500 5008 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: "Totalizer function for analogue signals" | Z500 5009 | CS-instrument/CSInstrument/CS Instrument | ||||
External Gateway PROFIBUS for RS 485 interface connection | Z500 3008 | CS-instrument/CSInstrument/CS Instrument | ||||
External Gateway PROFINET for RS 485 interface connection | Z500 3009 | CS-instrument/CSInstrument/CS Instrument | ||||
Software: - Phần mềm | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 5 DS 500) - database (MySQL) to Server - data evaluation via Client-Software |
0554 7041 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 10 DS 500) - database (MySQL) to Server - data evaluation via Client-Software |
0554 7042 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 20 DS 500) - database (MySQL) to Server - data evaluation via Client-Software |
0554 7043 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (> 20 DS 500) - database (MySQL) to Server - data evaluation via Client-Software |
0554 7044 | CS-instrument/CSInstrument/CS Instrument | ||||
Software Support / h | 9999 9998 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 - cảm biến dòng (dành cho khí/ gas) | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA 500 flow sensor, with RS 485 interface (Modbus-RTU), with analogue output 4...20mA and pulse output (galvanically separated) | 0695 5001 | CS-instrument/CSInstrument/CS Instrument | ||||
Max. Version (185 m/s) | Z695 5003 | CS-instrument/CSInstrument/CS Instrument | ||||
HighSpeed version (224 m/s) | Z695 5002 | CS-instrument/CSInstrument/CS Instrument | ||||
Display | Z695 5000 | CS-instrument/CSInstrument/CS Instrument | ||||
M-Bus (pulse output not available) | Z695 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
9 | Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | |||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section - Cảm biến dòng khí gas phiên bản tích hợp chức năng đo dòng | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Option signal output / bus connection | CS-instrument/CSInstrument/CS Instrument | |||||
M-Bus (pulse output not available) | Z695 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Further accessories: | CS-instrument/CSInstrument/CS Instrument | |||||
Closing cap for measuring section in aluminium | 0190 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases - Cảm biến dòng khí cho dòng khí lưu lượng thấp | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 - cảm biến điểm sương | CS-instrument/CSInstrument/CS Instrument | |||||
9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber with inner threat G1/2" and mounted male coupling DN 7,2 for quick-lock coupling |
0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
More measuring chambers please see on catalogue page 60 | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cables for VA/FA sensors - Cáp kết nối | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors - cảm biến áp suất | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy ± 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors - cảm biến nhiệt độ | CS-instrument/CSInstrument/CS Instrument | |||||
9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Outdoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0203 | CS-instrument/CSInstrument/CS Instrument | ||||
Indoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0204 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors | CS-instrument/CSInstrument/CS Instrument | |||||
9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters - Máy đo khí dạng gắn ngoài | CS-instrument/CSInstrument/CS Instrument | |||||
9 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A TRMS incl. 3 m connection cable with open ends | 0554 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0…1000 A RMS, 4…20 mA = 0…1000 A, 10-30 VDC, 3 m connection cable with open ends | 0554 0518 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting - Đo dòng điện dạng gắn panel | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 10 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting, with RS 485 Interface |
0554 5355 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5344 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 200/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5345 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 300/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5346 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 500/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5347 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5348 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 65 x 32 mm) |
0554 5349 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 2000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 127 x 38 mm) |
0554 5350 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cable CS ENERIUM 30: | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable variable length, open ends on both sides | 0553 0126 | CS-instrument/CSInstrument/CS Instrument | ||||
DS 500 mobile - intelligent chart recorder | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 15 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Intelligent chart recorder DS 500 mobile, 4 sensor inputs | 0500 5012 | CS-instrument/CSInstrument/CS Instrument | ||||
Intelligent chart recorder DS 500 mobile, 8 sensor inputs | 0500 5013 | CS-instrument/CSInstrument/CS Instrument | ||||
Intelligent chart recorder DS 500 mobile, 12 sensor inputs | 0500 5014 | CS-instrument/CSInstrument/CS Instrument | ||||
Option “integrated Webserver” | Z500 5003 | CS-instrument/CSInstrument/CS Instrument | ||||
Option “consumption report” statistics, daily/weekly/monthly report | Z500 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Option “mathematics calculat. function” for 4 freely selectable “virtual” channels, (mathematical functions: addition, subtraction, division, multiplication) |
Z500 5008 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: "Totalizer function for analogue signals" | Z500 5009 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Software: | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Energy Analyzer for energy and leakage analysis of compressed air stations | 0554 7050 | CS-instrument/CSInstrument/CS Instrument | ||||
Software Upgrade of the already existing CS Soft Basic to CS Soft Energy Analyzer | 0554 7045 | CS-instrument/CSInstrument/CS Instrument | ||||
GSM module for data transfer via the GSM network (mobile network) | on request | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for pressure,temperature or external sensors on mobile instruments, ODU / open ends, 5 m | 0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure,temperature or external sensors on mobile instruments, ODU / open ends, 10 m | 0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments,ODU / M 12, 5 m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 400 series on mobile instruments,ODU / M 12, 5 m | 0553 0503 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments,ODU / ODU, 10 m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for mobile current/effective power meter to DS 500 mobile, 5 m | 0553 0506 | CS-instrument/CSInstrument/CS Instrument | ||||
Adapter for connection cable ODU 5 to 8 pole for existing cable part no. 0553.0111 (for VA/FA sensors) from DS 300 mobile to DS 500 mobile |
0553 0507 | CS-instrument/CSInstrument/CS Instrument | ||||
Adapter for connection cable ODU 5 to 8 pole for existing cable part no. 0553.0110 (for analogue) from DS 300 mobile to DS 500 mobile |
0553 0508 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Case for all sensors (dimensions: 500 x 360 x 180 mm) | 0554 6006 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensors VA 500 - Cảm biến dòng khí gas | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500-Max. Version (185 m/s) sensor length 220 mm, incl. 5 m cable to mobile instruments |
0695 1124 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 High-Speed Version (224 m/s), sensor length 220 mm incl. 5 m cable to mobile instruments |
0695 1125 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section Cảm biến dòng khí VA 520 + chức năng đo lưu lượng khí tích hợp |
CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases - Cảm biến dòng khí cho dòng khí lưu lượng thấp | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 - cảm biến điểm sương | CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -80…+20°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -20…+50°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1512 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for VA/FA sensors - Cáp kết nối | CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments, ODU/M12, 5m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificates for flow sensors / dew point sensors - Chứng chỉ hiệu chuẩn cho cảm biến dòng khí và điểm sương | CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration for consumption sensors including ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors - cả biến áp suất khí | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy ± 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors - cảm biến nhiệt độ | CS-instrument/CSInstrument/CS Instrument | |||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Bendable temperature probe PT 100 (2-wire) class A, length: 300 mm, d=3 mm, -70°C to +500°C, connection cable PFA, 2 m with ODU-plug (8 pole) to mobile instruments |
0604 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Cross-band surface temperature probe, thermocouple Type K, with integrated transducer 4…20 mA = 0°C…+180°C, 2 m connection calbe (PVC) with ODU-plug (8-pole) to mobile instruments | 0604 0202 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors - cáp kết nối | CS-instrument/CSInstrument/CS Instrument | |||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature, or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters - Máy đo khí dạng gắn ngoài | CS-instrument/CSInstrument/CS Instrument | |||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A 10-30 VDC for mobile devices, 3 m cable,ODU 8 pin | 0554 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 10…1000 A RMS, 4…20 mA = 10…1000 A, 10-30 VDC, 3 m connection cable with ODU-plug (8 poles) for mobile devices |
0554 0519 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 32 A | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
CS PM 532 | CS-instrument/CSInstrument/CS Instrument | |||||
Current/effective power meter up to 32 A in a carrying case | 0554 5340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS PM 600 Current/effective power meter - Máy đo dòng | CS-instrument/CSInstrument/CS Instrument | |||||
26 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 100 A in a carrying case with connection cable 5 m | 0554 5341 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 600 A in a carrying case with connection cable 5 m | 0554 5342 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100A/1A consisting of 3 transformers for mobile devices | Z554 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600A/1A consisting of 3 transformers for mobile devices | Z554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000A/1A consisting of 3 transformers for mobile devices | Z554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 27 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting, with RS 485 Interface |
0554 5355 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5344 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 200/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5345 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 300/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5346 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 500/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5347 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5348 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 65 x 32 mm) |
0554 5349 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 2000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 127 x 38 mm) |
0554 5350 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cable CS ENERIUM 30: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for sensors 5 m, with open ends | 0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Mobile chart recorder DS 400 mobile | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 20 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Product | Sensor input 1+2 | Sensor input 3+4 | CS-instrument/CSInstrument/CS Instrument | |||
DS 400 mobile - mobile chart recorder with graphic display and touch screen | Digital | ---------- | 0500 4012 D | CS-instrument/CSInstrument/CS Instrument | ||
Digital | Digital | 0500 4012 DD | CS-instrument/CSInstrument/CS Instrument | |||
Digital | Analogue | 0500 4012 DA | CS-instrument/CSInstrument/CS Instrument | |||
Analogue | ---------- | 0500 4012 A | CS-instrument/CSInstrument/CS Instrument | |||
Analogue | Analogue | 0500 4012 AA | CS-instrument/CSInstrument/CS Instrument | |||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Integrated Ethernet- and RS 485 interface | Z500 4004 | CS-instrument/CSInstrument/CS Instrument | ||||
Integrated webserver | Z500 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
"Mathematics calculation function" for 4 freely selectable channels, (virtual channels): addition, subtraction, division, multiplication |
Z500 4007 | CS-instrument/CSInstrument/CS Instrument | ||||
"Totalizer function for analogue signals" | Z500 4006 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for analogue sensors (like: pressure, temperautre sensors ...) | Z500 4001 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for digital sensors (SDI/Modbus) | Z500 4003 | CS-instrument/CSInstrument/CS Instrument | ||||
Further Accessories: | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Energy Analyzer for energy and leakage analysis of compressed air stations | 0554 7050 | CS-instrument/CSInstrument/CS Instrument | ||||
Software Upgrade of the already existing CS Soft Basic to CS Soft Energy Analyzer | 0554 7045 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments,ODU / M 12, 5 m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 400 series on mobile instruments,ODU / M 12, 5 m | 0553 0503 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure,temperature or external sensors on mobile instruments, ODU / open ends, 5 m | 0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure,temperature or external sensors on mobile instruments, ODU / open ends, 10 m | 0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments,ODU / ODU, 10 m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for mobile current/effective power meter to DS 500 mobile, 5 m | 0553 0506 | CS-instrument/CSInstrument/CS Instrument | ||||
Case for all sensors (Dimensions: 500 x 360 x 120 mm) | 0554 6006 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 - cảm biến dòng (dành cho khí/ gas) | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500-Max. Version (185 m/s) sensor length 220 mm, incl. 5 m cable to mobile instruments |
0695 1124 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 High-Speed Version (224 m/s), sensor length 220 mm incl. 5 m cable to mobile instruments |
0695 1125 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section | CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases - Cảm biến dòng khí cho dòng khí lưu lượng thấp | ||||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 - cảm biến điểm sương | ||||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -80…+20°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -20…+50°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1512 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for VA/FA sensors- cáp kết nối | CS-instrument/CSInstrument/CS Instrument | |||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments, ODU/M12, 5m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificates for flow sensors / dew point sensors - Chứng chỉ hiệu chuẩn cho cảm biến dòng khí và điểm sương | ||||||
24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration for consumption sensors including ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors - cảm biến áp suất | ||||||
Catalogue page 24 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy < 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors - cảm biến nhiệt độ | ||||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Bendable temperature probe PT 100 (2-wire) class A, length: 300 mm, d=3 mm, -70°C to +500°C, connection cable PFA, 2 m with ODU-plug (8 pole) to mobile instruments |
0604 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Cross-band surface temperature probe, thermocouple Type K, with integrated transducer 4…20 mA = 0°C…+180°C, 2 m connection calbe (PVC) with ODU-plug (8-pole) to mobile instruments | 0604 0202 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors - cáp kết nối | ||||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature, or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters - Máy đo khí dạng gắn ngoài | ||||||
25 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A 10-30 VDC for mobile devices, 3 m cable,ODU 8 pin | 0554 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 10…1000 A RMS, 4…20 mA = 10…1000 A, 10-30 VDC, 3 m connection cable with ODU-plug (8 poles) for mobile devices |
0554 0519 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 32 A | ||||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
CS PM 532 | CS-instrument/CSInstrument/CS Instrument | |||||
Current/effective power meter up to 32 A in a carrying case | 0554 5340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS PM 600 Current/effective power meter | ||||||
26 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 100 A in a carrying case with connection cable 5 m | 0554 5341 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 600 A in a carrying case with connection cable 5 m | 0554 5342 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100A/1A consisting of 3 transformers for mobile devices | Z554 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600A/1A consisting of 3 transformers for mobile devices | Z554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000A/1A consisting of 3 transformers for mobile devices | Z554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30Current/effective power meter for panel mounting | ||||||
Catalogue page 27 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting, with RS 485 Interface |
0554 5355 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5344 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 200/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5345 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 300/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5346 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 500/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5347 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5348 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 65 x 32 mm) |
0554 5349 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 2000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 127 x 38 mm) |
0554 5350 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cable CS ENERIUM 30: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for sensors 5 m, with open ends | 0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable Hand-held instrument PI 500 - Máy đo khí dạng cầm tay | CS-instrument/CSInstrument/CS Instrument | |||||
30 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
PI 500 portable measuring instrument with integrated data logger, incl. power supply | 0560 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Option for PI 500: “mathematics calculat. function” for 4 freely selectable "virtual" channels | Z500 5107 | CS-instrument/CSInstrument/CS Instrument | ||||
Option for PI 500: "Totalizer function for analogue signals" | Z500 5106 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
Transportation case | 0554 6510 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 - cảm biến dòng (dành cho khí/ gas) | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500-Max. Version (185 m/s) sensor length 220 mm, incl. 5 m cable to mobile instruments |
0695 1124 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 High-Speed Version (224 m/s), sensor length 220 mm incl. 5 m cable to mobile instruments |
0695 1125 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section - Cảm biến dòng khí gas phiên bản tích hợp chức năng đo dòng | CS-instrument/CSInstrument/CS Instrument | |||||
31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases - Cảm biến dòng khí cho dòng khí lưu lượng thấp | ||||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 - cảm biến điểm sương | ||||||
31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -80…+20°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -20…+50°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1512 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for VA/FA sensors - cáp kết nối | ||||||
31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments, ODU/M12, 5m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificates for flow sensors / dew point sensors | ||||||
31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration for consumption sensors including ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors - cảm biến áp suất | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy < 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors -cảm biến nhiệt độ khí gas | ||||||
31 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Bendable temperature probe PT 100 (2-wire) class A, length: 300 mm, d=3 mm, -70°C to +500°C, connection cable PFA, 2 m with ODU-plug (8 pole) to mobile instruments |
0604 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Cross-band surface temperature probe, thermocouple Type K, with integrated transducer 4…20 mA = 0°C…+180°C, 2 m connection calbe (PVC) with ODU-plug (8-pole) to mobile instruments | 0604 0202 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors- cáp kết nối | ||||||
32 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature, or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters - Máy đo khí dạng gắn ngoài | ||||||
32 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A 10-30 VDC for mobile devices, 3 m cable,ODU 8 pin | 0554 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 10…1000 A RMS, 4…20 mA = 10…1000 A, 10-30 VDC, 3 m connection cable with ODU-plug (8 poles) for mobile devices |
0554 0519 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 32 A | ||||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
CS PM 532 | CS-instrument/CSInstrument/CS Instrument | |||||
Current/effective power meter up to 32 A in a carrying case | 0554 5340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS PM 600 Current/effective power meter - máy đo dòng | ||||||
32 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 100 A in a carrying case with connection cable 5 m | 0554 5341 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 600 A in a carrying case with connection cable 5 m | 0554 5342 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100A/1A consisting of 3 transformers for mobile devices | Z554 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600A/1A consisting of 3 transformers for mobile devices | Z554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000A/1A consisting of 3 transformers for mobile devices | Z554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 500 | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 41 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Set DP 500 in a case - consisting of: | 0600 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 500 for compressed air and gases | 0560 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Mobile measuring chamber up to 16 bar | 0699 4490 | CS-instrument/CSInstrument/CS Instrument | ||||
Diffusion-tight teflon hose 1 m with fast coupling at both ends | 0554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Power supply for DP 500/510 | 0554 0009 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Quick-lock coupling | 0530 1101 | CS-instrument/CSInstrument/CS Instrument | ||||
Dry container for CS dew point sensors | 0699 2500 | CS-instrument/CSInstrument/CS Instrument | ||||
Transportation case (small) for DP 500 | 0554 6500 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Further options, not included in the set - Lựa chọn thêm | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 500 (high pressure version up to 350 bar) | 0560 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
High-pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for granulate dryers for minimum over pressure | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75.3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Additional calibration point freely selectable in the range between -80…+20°Ctd | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 510 with external sensor input - cảm biến điểm sương dạng cầm tay - tích hợp thêm cảm biến đầu vào | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 44 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Set DP 510 in a case - consisting of: | 0600 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 510 with one additional sensor input | 0560 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Mobile measuring chamber up to 16 bar | 0699 4490 | CS-instrument/CSInstrument/CS Instrument | ||||
Diffusion-tight teflon hose 1 m with fast coupling at both ends | 0554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Power supply for DP 500/510 | 0554 0009 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Quick-lock coupling | 0530 1101 | CS-instrument/CSInstrument/CS Instrument | ||||
Dry container for CS dew point sensors | 0699 2500 | CS-instrument/CSInstrument/CS Instrument | ||||
Transportation case (big) for DP 510 as well as further sensors | 0554 6510 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Further options, not included in the set - Lựa chọn thêm | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet | 0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
Option for DP 510: “mathematics calculat. function” for 4 freely selectable “virtual” channels | Z500 5107 | CS-instrument/CSInstrument/CS Instrument | ||||
Option for DP 510: "Totalizer function for analogue signals" | Z500 5106 | CS-instrument/CSInstrument/CS Instrument | ||||
Portable dew point meter DP 510 for compressed air and gases (high pressure version up to 350 bar) |
0560 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
High-pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for granulate dryers for minimum over pressure | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75.3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Additional calibration point freely selectable in the range between -80…+20°Ctd | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 - cảm biến dòng (dành cho khí/ gas) | ||||||
Catalogue page 45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500-Max. Version (185 m/s) sensor length 220 mm, incl. 5 m cable to mobile instruments |
0695 1124 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 High-Speed Version (224 m/s), sensor length 220 mm incl. 5 m cable to mobile instruments |
0695 1125 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section - Cảm biến dòng khí gas phiên bản tích hợp chức năng đo dòng | ||||||
45 | Order no. | |||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -80…+20°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for mobile instruments, -20…+50°Ctd incl. mobile measuring chamber, 5 m cable and perforated cap |
0699 1512 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for VA/FA sensors | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA 5xx series on mobile instruments, ODU/M12, 5m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificates for flow sensors / dew point sensors | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration for consumption sensors including ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors - cảm biến áp suất | ||||||
Catalogue page 45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy < 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors - cảm biến nhiệt độ khí gas | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Bendable temperature probe PT 100 (2-wire) class A, length: 300 mm, d=3 mm, -70°C to +500°C, connection cable PFA, 2 m with ODU-plug (8 pole) to mobile instruments |
0604 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Cross-band surface temperature probe, thermocouple Type K, with integrated transducer 4…20 mA = 0°C…+180°C, 2 m connection calbe (PVC) with ODU-plug (8-pole) to mobile instruments | 0604 0202 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors - cáp kết nối | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature, or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Mounted Odu plug for connection on mobile instruments | Z604 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters - Máy đo khí dạng gắn ngoài | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A 10-30 VDC for mobile devices, 3 m cable,ODU 8 pin | 0554 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 10…1000 A RMS, 4…20 mA = 10…1000 A, 10-30 VDC, 3 m connection cable with ODU-plug (8 poles) for mobile devices |
0554 0519 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 32 A | ||||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
CS PM 532 | CS-instrument/CSInstrument/CS Instrument | |||||
Current/effective power meter up to 32 A in a carrying case | 0554 5340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS PM 600 Current/effective power meter - máy đo dòng | ||||||
45 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 100 A in a carrying case with connection cable 5 m | 0554 5341 | CS-instrument/CSInstrument/CS Instrument | ||||
Current/effective power meter up to 600 A in a carrying case with connection cable 5 m | 0554 5342 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100A/1A consisting of 3 transformers for mobile devices | Z554 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600A/1A consisting of 3 transformers for mobile devices | Z554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000A/1A consisting of 3 transformers for mobile devices | Z554 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
DP 400 mobile with integrated dew point and pressure measurement - Máy đo dòng di động có tích hợp cảm biến điểm sương và áp suất | ||||||
Catalogue page 47 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
DP 400 mobile - Portable dew point meter with integrated pressure measurement, incl. transportation bag for teflon hose and power supply |
0500 4505 | CS-instrument/CSInstrument/CS Instrument | ||||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Option: Integrated data logger for 100 million measured values | Z500 4002 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: Integrated Ethernet- and RS 485 interface | Z500 4004 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: Integrated webserver | Z500 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: “mathematics calculat. function” for 4 freely selectable “virtual” channels | Z500 4007 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: 2 additional sensor inputs for external sensors (1 x digital sensor Modbus, 1 x analogue sensor) |
Z500 4001 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA 5xx series on mobile instruments, ODU/M12, 5m | 0553 1503 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
Extension cable for mobile instruments ODU/ODU, 10m | 0553 0504 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510/515 for desiccant driers - cảm biến điểm sương | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 50 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 515 dew point sensor for desiccat driers incl. inspection certificate, 4…20 mA output signal (2-wire connection) or Modbus-RTU interface | 0699 0515 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Additional costs FA 510, FA 515 dew point sensors: lựa chọn thêm cho cảm biến điêm sương | CS-instrument/CSInstrument/CS Instrument | |||||
Measuring ranges: | CS-instrument/CSInstrument/CS Instrument | |||||
-80…+20°Ctd (-112 to 68°F) | CS-instrument/CSInstrument/CS Instrument | |||||
-80...+20°Ctd (output scaling 4...20 mA = -100…+20°Ctd) | CS-instrument/CSInstrument/CS Instrument | |||||
-80…+20°Ctd (output scaling 4…20 mA = -110…+20°Ctd) | CS-instrument/CSInstrument/CS Instrument | |||||
Analogue output: | CS-instrument/CSInstrument/CS Instrument | |||||
4…20 mA (3-Draht) | CS-instrument/CSInstrument/CS Instrument | |||||
Special version 2…10 Volt | Z699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Scaling: | CS-instrument/CSInstrument/CS Instrument | |||||
Standard | CS-instrument/CSInstrument/CS Instrument | |||||
Special scaling: 4…20 mA=__ … __ g/m³, ppm etc. | Z699 0514 | CS-instrument/CSInstrument/CS Instrument | ||||
Connector plug: | CS-instrument/CSInstrument/CS Instrument | |||||
M12 plug | CS-instrument/CSInstrument/CS Instrument | |||||
M12 plug (90°) angled | CS-instrument/CSInstrument/CS Instrument | |||||
Max. pressure: | CS-instrument/CSInstrument/CS Instrument | |||||
50 bar | CS-instrument/CSInstrument/CS Instrument | |||||
350 bar | Z699 0515 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface condition: | CS-instrument/CSInstrument/CS Instrument | |||||
Normal | CS-instrument/CSInstrument/CS Instrument | |||||
Free of oil & grease | Z699 0517 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 5 m with 90° offset M12 plug | 0553 0118 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 10 m with 90° offset M12 plug | 0553 0119 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m shielded | 0553 0129 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m shielded | 0553 0130 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Measuring chambers: | CS-instrument/CSInstrument/CS Instrument | |||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
High pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring Chamber for granulate dryers up to 250 mbar | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | CS-instrument/CSInstrument/CS Instrument | ||||
Quick-lock coupling NW 7,2 sealing tape | 0530 1101 | CS-instrument/CSInstrument/CS Instrument | ||||
50 | CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | CS-instrument/CSInstrument/CS Instrument | |||
CS-instrument/CSInstrument/CS Instrument | ||||||
Mains units: | CS-instrument/CSInstrument/CS Instrument | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | CS-instrument/CSInstrument/CS Instrument | ||||
Transformer 100-240 V AC/24 V DC , 0,35 A on top-hat rail | 0699 3340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -80 to 20°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Replacement unit for the period of re-calibration | 0699 3900 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point meter in exchange with calibration certificate at -40° Ctd | 0699 3990 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 52 for desiccant driers | ||||||
Catalogue page 51 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 52 for desiccant driers | 0600 5100 | CS-instrument/CSInstrument/CS Instrument | ||||
consisting of: | CS-instrument/CSInstrument/CS Instrument | |||||
DS 52 LED display in wall housing | 0500 0009 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Power supply 24 VDC (instead of 230 VAC) | Z500 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Power supply 110 VAC (instead of 230 VAC) | Z500 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm unit mounted at wall housing | Z500 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm unit for external mounting with 5 m cable | Z500 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Connecting cable version Switzerland - three-pole | Z553.CH | CS-instrument/CSInstrument/CS Instrument | ||||
Connecting cable version USA - three-pole | Z553.USA | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -80 to 20°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510/515 for refrigeration driers | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 52 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 515 dew point sensor for refrigeration driers incl. inspection certificate, 4…20 mA output signal (2-wire connection) or Modbus-RTU interface | 0699 0517 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Additional costs FA 510, FA 515 dew point sensors: | CS-instrument/CSInstrument/CS Instrument | |||||
Measuring ranges: | CS-instrument/CSInstrument/CS Instrument | |||||
-20…+50°Ctd (-4 to 122 °F) | CS-instrument/CSInstrument/CS Instrument | |||||
-40…+30°Ctd (-40 to 86°F) | on request | CS-instrument/CSInstrument/CS Instrument | ||||
-45…+70°Ctd (-49 to 158 °F) | on request | CS-instrument/CSInstrument/CS Instrument | ||||
-60…+30°Ctd (-76 to 86°F) | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Analogue output: | CS-instrument/CSInstrument/CS Instrument | |||||
4…20 mA (3-Draht) | CS-instrument/CSInstrument/CS Instrument | |||||
Special version 2…10 Volt | Z699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Scaling: | CS-instrument/CSInstrument/CS Instrument | |||||
Standard | CS-instrument/CSInstrument/CS Instrument | |||||
Special scaling: 4…20 mA=__ … __ g/m³, ppm etc. | Z699 0514 | CS-instrument/CSInstrument/CS Instrument | ||||
Connector plug: | CS-instrument/CSInstrument/CS Instrument | |||||
M12 plug | CS-instrument/CSInstrument/CS Instrument | |||||
M12 plug (90°) angled | CS-instrument/CSInstrument/CS Instrument | |||||
Max. pressure: | CS-instrument/CSInstrument/CS Instrument | |||||
50 bar | CS-instrument/CSInstrument/CS Instrument | |||||
350 bar | Z699 0515 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface condition: | CS-instrument/CSInstrument/CS Instrument | |||||
Normal | CS-instrument/CSInstrument/CS Instrument | |||||
Free of oil & grease | Z699 0517 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 5 m with 90° offset M12 plug | 0553 0118 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 10 m with 90° offset M12 plug | 0553 0119 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m shielded | 0553 0129 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m shielded | 0553 0130 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Measuring chambers: | CS-instrument/CSInstrument/CS Instrument | |||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
High pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring Chamber for granulate dryers up to 250 mbar | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | CS-instrument/CSInstrument/CS Instrument | ||||
52 | Quick-lock coupling NW 7,2 sealing tape | 0530 1101 | CS-instrument/CSInstrument/CS Instrument | |||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Mains units: | CS-instrument/CSInstrument/CS Instrument | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | CS-instrument/CSInstrument/CS Instrument | ||||
Transformer 100-240 V AC/24 V DC , 0,35 A on top-hat rail | 0699 3340 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -20 to 50°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Replacement unit for the period of re-calibration | 0699 3900 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point meter in exchange with calibration certificate at -40° Ctd | 0699 3990 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 52 for refrigeration driers | ||||||
Catalogue page 53 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 52 for refrigeration driers | 0600 5120 | CS-instrument/CSInstrument/CS Instrument | ||||
consisting of: | CS-instrument/CSInstrument/CS Instrument | |||||
DS 52 LED display in wall housing | 0500 0009 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Power supply 24 VDC (instead of 230 VAC) | Z500 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Power supply 110 VAC (instead of 230 VAC) | Z500 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm unit mounted at wall housing | Z500 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm unit for external mounting with 5 m cable | Z500 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Connecting cable version Switzerland - three-pole | Z553.CH | CS-instrument/CSInstrument/CS Instrument | ||||
Connecting cable version USA - three-pole | Z553.USA | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -20 to 50°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 400 | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 54 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point set DS 400 for desiccant driers (-80…+20°Ctd) | 0601 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
consisting of: | CS-instrument/CSInstrument/CS Instrument | |||||
Chart recorder DS 400 | 0500 4000 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface (-80…+20°Ctd) | 0699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Dew point set DS 400 for refrigeration driers (-20…+50°Ctd) | 0601 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
consisting of: | CS-instrument/CSInstrument/CS Instrument | |||||
Chart recorder DS 400 | 0500 4000 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface (-20…+50°Ctd) | 0699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Optionen: | CS-instrument/CSInstrument/CS Instrument | |||||
Integrated data logger for 100 million measured values | Z500 4002 | CS-instrument/CSInstrument/CS Instrument | ||||
Integrierte Ethernet- und RS 485 Schnittstelle | Z500 4004 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for analogue sensors (like: pressure, temperautre sensors ...) | Z500 4001 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for digital sensors (SDI/Modbus) | Z500 4003 | CS-instrument/CSInstrument/CS Instrument | ||||
Integrated Webserver | Z500 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm device assembled | Z500 0003 | CS-instrument/CSInstrument/CS Instrument | ||||
Alarm device for external assembly incl. 5 m cable | Z500 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
DS 400 - Chart recorder | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 56 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Product | sensor- input 1+2 |
sensor- input 3+4 |
CS-instrument/CSInstrument/CS Instrument | |||
Chart recorder DS400 - with 3.5“ graphic display - easy operation with touch screen | digital | ---------- | 0500 4000 D | CS-instrument/CSInstrument/CS Instrument | ||
digital | digital | 0500 4000 DD | CS-instrument/CSInstrument/CS Instrument | |||
digital | analogue | 0500 4000 DA | CS-instrument/CSInstrument/CS Instrument | |||
analogue | ---------- | 0500 4000 A | CS-instrument/CSInstrument/CS Instrument | |||
analogue | analogue | 0500 4000 AA | CS-instrument/CSInstrument/CS Instrument | |||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Integrated data logger for 100 Mio. measured values | Z500 4002 | CS-instrument/CSInstrument/CS Instrument | ||||
Integrated Ethernet- and RS 485 interface | Z500 4004 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for analogue sensors (like: pressure, temperautre sensors ...) | Z500 4001 | CS-instrument/CSInstrument/CS Instrument | ||||
2 additional sensor inputs for digital sensors (SDI/Modbus) | Z500 4003 | CS-instrument/CSInstrument/CS Instrument | ||||
External Gateway PROFIBUS for RS 485 interface connection | Z500 3008 | CS-instrument/CSInstrument/CS Instrument | ||||
External Gateway PROFINET for RS 485 interface connection | Z500 3009 | CS-instrument/CSInstrument/CS Instrument | ||||
Option Integrated Webserver DS400 | Z500 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
Option “mathematics calculat. function” for 4 freely selectable “virtual” channels | Z500 4007 | CS-instrument/CSInstrument/CS Instrument | ||||
Option "Totalizer function for analogue signals" | Z500 4006 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Further options: | CS-instrument/CSInstrument/CS Instrument | |||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 5 DS 400) - database (MySQL) to Server - data evaluation via Client-Software | 0554 7041 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 10 DS 400) - data base (MySQL) to server - data evaluation via Client-Software | 0554 7042 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (up to 20 DS 400) - data base (MySQL) to server - data evaluation via Client-Software | 0554 7043 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Soft Network - Database Client/Server Solution (> 20 DS 400) - data base (MySQL) to server - data evaluation via Client-Software | 0554 7044 | CS-instrument/CSInstrument/CS Instrument | ||||
Software Support / h | 9999 9998 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Ready for plug in and parametrization | 0990 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Everything ready for plug in | 0990 0011 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 500 | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA 500 flow sensor, with RS 485 interface (Modbus-RTU), with analogue output 4...20mA and pulse output (galvanically separated) | 0695 5001 | CS-instrument/CSInstrument/CS Instrument | ||||
Max. Version (185 m/s) | Z695 5003 | CS-instrument/CSInstrument/CS Instrument | ||||
HighSpeed version (224 m/s) | Z695 5002 | CS-instrument/CSInstrument/CS Instrument | ||||
Display | Z695 5000 | CS-instrument/CSInstrument/CS Instrument | ||||
M-Bus (pulse output not available) | Z695 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 120 mm | ZSL 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 160 mm | ZSL 0160 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 220 mm | ZSL 0220 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 300 mm | ZSL 0300 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 400 mm | ZSL 0400 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 500 mm | ZSL 0500 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 600 mm | ZSL 0600 | CS-instrument/CSInstrument/CS Instrument | ||||
Sensor length 700 mm | ZSL 0700 | CS-instrument/CSInstrument/CS Instrument | ||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | CS-instrument/CSInstrument/CS Instrument | ||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Oil and fat free, special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Flow sensor VA 520 with integrated measuring section | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | CS-instrument/CSInstrument/CS Instrument | ||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Option signal output / bus connection | CS-instrument/CSInstrument/CS Instrument | |||||
M-Bus (pulse output not available) | Z695 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | CS-instrument/CSInstrument/CS Instrument | ||||
Option: special cleaning | 0699 4005 | CS-instrument/CSInstrument/CS Instrument | ||||
57 | 5 point precision calibration with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | |||
Real gas calibration | 3200 0015 | CS-instrument/CSInstrument/CS Instrument | ||||
Real gas calibration for mixed gases | on request | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Further accessories: | CS-instrument/CSInstrument/CS Instrument | |||||
Closing cap for measuring section in aluminium | 0190 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | CS-instrument/CSInstrument/CS Instrument | ||||
Flow measurment VA 500/ VA 520 for below gases | CS-instrument/CSInstrument/CS Instrument | |||||
Order no. | CS-instrument/CSInstrument/CS Instrument | |||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point sensors FA 510 | CS-instrument/CSInstrument/CS Instrument | |||||
57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber with inner threat G1/2" and mounted male coupling DN 7,2 for quick-lock coupling |
0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
More measuring chambers please see on catalogue page 60 | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cables for VA/FA sensors | CS-instrument/CSInstrument/CS Instrument | |||||
57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Pressure sensors -cảm biến áp suất | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | CS-instrument/CSInstrument/CS Instrument | ||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision pressure sensor CS (0..0.6 bar) accuracy < 0.5 % | 0694 3549 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature sensors - cảm biến nhiệt độ | CS-instrument/CSInstrument/CS Instrument | |||||
57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Outdoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0203 | CS-instrument/CSInstrument/CS Instrument | ||||
Indoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0204 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | CS-instrument/CSInstrument/CS Instrument | ||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | CS-instrument/CSInstrument/CS Instrument | ||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cables for pressure/temperature sensors | CS-instrument/CSInstrument/CS Instrument | |||||
57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on meters | CS-instrument/CSInstrument/CS Instrument | |||||
57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0...400 A TRMS incl. 3 m connection cable with open ends | 0554 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Clamp-on ammeter 0…1000 A RMS, 4…20 mA = 0…1000 A, 10-30 VDC, 3 m connection cable with open ends | 0554 0518 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 57 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
CS ENERIUM 30 Current/effective power meter for panel mounting, with RS 485 Interface |
0554 5355 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 100/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5344 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 200/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5345 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 300/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5346 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 500/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5347 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 600/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5348 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 1000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 65 x 32 mm) |
0554 5349 | CS-instrument/CSInstrument/CS Instrument | ||||
Current transformer 2000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 127 x 38 mm) |
0554 5350 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cable CS ENERIUM 30: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable variable length, open ends on both sides | 0553 0126 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 500 dew point monitoring - Thiết bị giám sát điểm sương | ||||||
Catalogue page 61 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 500 dew point sensor for refrigeration driers, -20...50°Ctd | 0699 0501 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 500 dew point sensor for desiccant driers, -80...20°Ctd | 0699 0502 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 500 dew point sensor, -60...30°Ctd | 0699 0503 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Ethernet-Interface for VA500/VA520, FA500 | Z695 5006 | CS-instrument/CSInstrument/CS Instrument | ||||
Ethernet-Interface PoE for VA500/VA520, FA500 | Z695 5007 | CS-instrument/CSInstrument/CS Instrument | ||||
M-Bus (pulse output not available) | Z695 5004 | CS-instrument/CSInstrument/CS Instrument | ||||
Option analogue output FA5xx, Special version 2…10 Volt | Z699 0510 | CS-instrument/CSInstrument/CS Instrument | ||||
Option max. pressure FA5xx 350 bar | Z699 0515 | CS-instrument/CSInstrument/CS Instrument | ||||
Option max. pressure FA5xx 500 bar | Z699 0516 | CS-instrument/CSInstrument/CS Instrument | ||||
Option special scaling FA5xx 4…20 mA=__ … __ g/m³, ppm etc. | Z699 0514 | CS-instrument/CSInstrument/CS Instrument | ||||
Option connection thread FA5xx, 5/8" UNF | Z699 0511 | CS-instrument/CSInstrument/CS Instrument | ||||
Option connection thread FA5xx, 1/2" NPT | Z699 0512 | CS-instrument/CSInstrument/CS Instrument | ||||
Option surface condition FA5xx, free of oil & grease | Z699 0517 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Connection cables: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 5 m shielded | 0553 0129 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA, 10 m shielded | 0553 0130 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 5 m with 90° offset M12 plug | 0553 0118 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for VA/FA sensors, 10 m with 90° offset M12 plug | 0553 0119 | CS-instrument/CSInstrument/CS Instrument | ||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m | 0553 0106 | CS-instrument/CSInstrument/CS Instrument | ||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m | 0553 0107 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Measuring chambers: | CS-instrument/CSInstrument/CS Instrument | |||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
High pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring Chamber for granulate dryers up to 250 mbar | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | CS-instrument/CSInstrument/CS Instrument | ||||
Quick-lock coupling NW 7,2 sealing tape | 0530 1101 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Power supply: | CS-instrument/CSInstrument/CS Instrument | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | CS-instrument/CSInstrument/CS Instrument | ||||
Transformer 100-240 V AC/24 V DC , 0,35 A on top-hat rail | 0699 3340 | CS-instrument/CSInstrument/CS Instrument | ||||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration and adjustment: | CS-instrument/CSInstrument/CS Instrument | |||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -80 to 20°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
FA 515 Ex Dew point measurement in explosive areas | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 62 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
FA 515 Ex pressure dew point meter (-80 to 20°Ctd) | 0699 5515 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Options: | CS-instrument/CSInstrument/CS Instrument | |||||
Special scaling, Analogue output to other humidity parameters: % RH g/m3, mg/m3, ppm V/V, g/kg |
Z699 0514 | CS-instrument/CSInstrument/CS Instrument | ||||
Intrinsically safe power supply, safety barriers | 0554 3071 | CS-instrument/CSInstrument/CS Instrument | ||||
High pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Mains units: | CS-instrument/CSInstrument/CS Instrument | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | CS-instrument/CSInstrument/CS Instrument | ||||
Mains unit on DIN rail, 100-240 VAC / 24 VDC, 0.35 A | 0699 3340 | CS-instrument/CSInstrument/CS Instrument | ||||
Mains unit 100-240 VAC/24 VDC, 0.35 A for Series VA/FA 400, 2 m cable | 0554 0107 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chambers | ||||||
63 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Standard measuring chamber up to 16 bar | 0699 3390 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for atmospheric dew point | 0699 3690 | CS-instrument/CSInstrument/CS Instrument | ||||
High pressure measuring chamber up to 350 bar | 0699 3590 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber for granulate dryers for minimum over pressure | 0699 3490 | CS-instrument/CSInstrument/CS Instrument | ||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | CS-instrument/CSInstrument/CS Instrument | ||||
Calibration and adjustments of new devices - Dich vụ hiệu chuẩn | CS-instrument/CSInstrument/CS Instrument | |||||
64 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration at -40 °Ctd or 3°Ctd including ISO certificate | 0699 3396 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -80 to 20°Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 11.3% RH | 0554 0002 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 33 % RH | 0554 0004 | CS-instrument/CSInstrument/CS Instrument | ||||
Control and calibration set 75,3 % RH | 0554 0005 | CS-instrument/CSInstrument/CS Instrument | ||||
Re-calibration (not discountable) | CS-instrument/CSInstrument/CS Instrument | |||||
64 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
Precision re-calibration at -40°C dew point with ISO certificate | 0699 3333 | CS-instrument/CSInstrument/CS Instrument | ||||
Precision calibration in the range of -80 to 20° Ctd, one additional point, freely selectable | 0700 7710 | CS-instrument/CSInstrument/CS Instrument | ||||
Replacement unit for the period of re-calibration | 0699 3900 | CS-instrument/CSInstrument/CS Instrument | ||||
Dew point meter in exchange with calibration certificate at -40° Ctd | 0699 3990 | CS-instrument/CSInstrument/CS Instrument | ||||
VA 550 Flow sensor | CS-instrument/CSInstrument/CS Instrument | |||||
Catalogue page 79 + 80 | Order no. | CS-instrument/CSInstrument/CS Instrument | ||||
VA 550 Flow sensor, measuring head in robust aluminium die cast housing | 0695 0550 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Measuring range: | Bestell-Code | CS-instrument/CSInstrument/CS Instrument | ||||
A1 - Standard version (92,7 m/s) | A1 | CS-instrument/CSInstrument/CS Instrument | ||||
A2 - Max version (185 m/s) | A2 | CS-instrument/CSInstrument/CS Instrument | ||||
A3 - High-Speed version (224 m/s) | A3 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Screw-in thread: | CS-instrument/CSInstrument/CS Instrument | |||||
B1 - G 1/2" outer thread | B1 | CS-instrument/CSInstrument/CS Instrument | ||||
B2 - NPT 1/2" outer thread | B2 | CS-instrument/CSInstrument/CS Instrument | ||||
B3 - PT 1/2" outer thread | B3 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Mounting length / shaft length: | CS-instrument/CSInstrument/CS Instrument | |||||
C1 - 220 mm | C1 | CS-instrument/CSInstrument/CS Instrument | ||||
C2 - 300 mm | C2 | CS-instrument/CSInstrument/CS Instrument | ||||
C3 - 400 mm | C3 | CS-instrument/CSInstrument/CS Instrument | ||||
C4 - 500 mm | C4 | CS-instrument/CSInstrument/CS Instrument | ||||
C5 - 600 mm | C5 | CS-instrument/CSInstrument/CS Instrument | ||||
C7 - 160 mm | C7 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Option display: | CS-instrument/CSInstrument/CS Instrument | |||||
D1 - with integrated display | D1 | CS-instrument/CSInstrument/CS Instrument | ||||
D2 - without display | D2 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Option signal outputs / bus connection: | CS-instrument/CSInstrument/CS Instrument | |||||
E1 - 2x4...20mA a. output,galv.isolated,pulse output RS485 Modbus-RTU | E1 | CS-instrument/CSInstrument/CS Instrument | ||||
E4 - 1x4…20mA analogue output (not galv. isolated), pulse output, RS 485 (Modbus RTU) | E4 | CS-instrument/CSInstrument/CS Instrument | ||||
E5 - Ethernet-Interface (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU) | E5 | CS-instrument/CSInstrument/CS Instrument | ||||
E7 - 2x4..20mA analogue output passive,pulse output RS485 (Mb-RTU) | E7 | CS-instrument/CSInstrument/CS Instrument | ||||
Catalogue page 79 + 80 | E8 - M-Bus (Z6955504) | E8 | CS-instrument/CSInstrument/CS Instrument | |||
E9 - Ethernet-Interface PoE (Power over Ethernet) (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU) | E9 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Calibration: | CS-instrument/CSInstrument/CS Instrument | |||||
F1 - no real gas calibration - gas adjustment via gas constant | F1 | CS-instrument/CSInstrument/CS Instrument | ||||
F2 - real gas calibration in the gas type as selected below | F2 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Gas type: | CS-instrument/CSInstrument/CS Instrument | |||||
G1 - Compressed air | G1 | CS-instrument/CSInstrument/CS Instrument | ||||
G2 - Nitrogen (N2) | G2 | CS-instrument/CSInstrument/CS Instrument | ||||
G3 - Argon (Ar) | G3 | CS-instrument/CSInstrument/CS Instrument | ||||
G4 - Carbon dioxide (CO2) | G4 | CS-instrument/CSInstrument/CS Instrument | ||||
G5 - Oxygen (O2) | G5 | CS-instrument/CSInstrument/CS Instrument | ||||
G6 - Nitrous Oxide (N2O) | G6 | CS-instrument/CSInstrument/CS Instrument | ||||
G7 - Natural gas (NG) | G7 | CS-instrument/CSInstrument/CS Instrument | ||||
G8 - Helium (He) - Real gas calibration required | G8 | CS-instrument/CSInstrument/CS Instrument | ||||
G9 - Propane (C3H8) - Real gas calibration required | G9 | CS-instrument/CSInstrument/CS Instrument | ||||
G10 - Methane (CH4) | G10 | CS-instrument/CSInstrument/CS Instrument | ||||
G11 - Biogas (Methane 50% : CO2 50%) | G11 | CS-instrument/CSInstrument/CS Instrument | ||||
G12 - Hydrogen (H2) - Real gas calibration required | G12 | CS-instrument/CSInstrument/CS Instrument | ||||
G90 -Further gas | G90 | CS-instrument/CSInstrument/CS Instrument | ||||
G91 - Gas mixture | G91 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Maximum pressure: | CS-instrument/CSInstrument/CS Instrument | |||||
H3 - 16 bar | H3 | CS-instrument/CSInstrument/CS Instrument | ||||
H1 - 50 bar (not for DVGW approval) | H1 | CS-instrument/CSInstrument/CS Instrument | ||||
H2 - 100 bar (not for DVGW approval) | H2 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Surface condition: | CS-instrument/CSInstrument/CS Instrument | |||||
I1 - Standard version | I1 | CS-instrument/CSInstrument/CS Instrument | ||||
I2 - Special cleaning - oil and grease free (e.g. for oxygen) | I2 | CS-instrument/CSInstrument/CS Instrument | ||||
I3 - LABS free and silicone free, special cleaning oil and grease free | I3 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Accuracy class: | CS-instrument/CSInstrument/CS Instrument | |||||
J1 - ± 1,5% of measured value (standard) | J1 | CS-instrument/CSInstrument/CS Instrument | ||||
J2 - ± 1 % of measured value (precision) | J2 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Maximum gas temperature at the sensor tip: | CS-instrument/CSInstrument/CS Instrument | |||||
K1 - up to 120°C gas temperature (only for ATEX - version) | K1 | CS-instrument/CSInstrument/CS Instrument | ||||
K2 - up to 180°C gas temperature (not for ATEX - version) | K2 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
Approvals: | CS-instrument/CSInstrument/CS Instrument | |||||
L1 - Non-explosive area - no approval | L1 | CS-instrument/CSInstrument/CS Instrument | ||||
L2 - ATEX II 2G Ex d IIC T4 | L2 | CS-instrument/CSInstrument/CS Instrument | ||||
79 + 80 | L3 - DVGW approval (for natural gas) | L3 | CS-instrument/CSInstrument/CS Instrument | |||
CS-instrument/CSInstrument/CS Instrument | ||||||
Reference conditions: | CS-instrument/CSInstrument/CS Instrument | |||||
M1 - 20°C, 1000 hPa | M1 | CS-instrument/CSInstrument/CS Instrument | ||||
M2 - 0°C, 1013,25 hPa | M2 | CS-instrument/CSInstrument/CS Instrument | ||||
M3 - 15°C, 981 hPa | M3 | CS-instrument/CSInstrument/CS Instrument | ||||
M4 - 15°C, 1013,25 hPa | M4 | CS-instrument/CSInstrument/CS Instrument | ||||
CS-instrument/CSInstrument/CS Instrument | ||||||
R1 - Special measuring range | R1 | CS-instrument/CSInstrument/CS Instrument | ||||
Further accessories: | CS-instrument/CSInstrument/CS Instrument | |||||
Connection cable for sensors 5 m with open ends | 0553 0108 | CS-instrument/CSInstrument/CS Instrument | ||||
Connection cable for sensors 10 m with open ends | 0553 0109 | CS-instrument/CSInstrument/CS Instrument | ||||
Ethernet connection cable length 5 m, M12 plug x-coded (8 poles) to RJ 45 plug | 0553 2503 | CS-instrument/CSInstrument/CS Instrument | ||||
Ethernet connection cable length 10 m, M12 plug x-coded (8 poles) to RJ 45 plug | 0553 2504 | CS-instrument/CSInstrument/CS Instrument | ||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | CS-instrument/CSInstrument/CS Instrument | ||||
Additional calibration point volume flow VA5xx serial, freely selectable | 0700 7720 | CS-instrument/CSInstrument/CS Instrument | ||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | CS-instrument/CSInstrument/CS Instrument | ||||
High-pressure protection f. installation from 10 to 100 bar (for VA 550) | 0530 1115 | CS-instrument/CSInstrument/CS Instrument | ||||
High-pressure protection f. installation from 10 to 16 bar DVGW (for VA 550) | 0530 1116 | CS-instrument/CSInstrument/CS Instrument | ||||
PNG cable screwing - standard | 0553 0552 | CS-instrument/CSInstrument/CS Instrument | ||||
PNG cable screwing – for ATEX | 0553 0551 | CS-instrument/CSInstrument/CS Instrument | ||||
VA 570 - Flow sensor with integrated measuring section | ||||||
Catalogue page 78 + 80 | Order no. | |||||
VA 570 Flow sensor with integrated 1/2" measuring section | 0695 0570 | |||||
VA 570 Flow sensor with integrated 3/4" measuring section | 0695 0571 | |||||
VA 570 Flow sensor with integrated 1" measuring section | 0695 0572 | |||||
VA 570 Flow sensor with integrated 1 1/4" measuring section | 0695 0573 | |||||
VA 570 Flow sensor with integrated 1 1/2" measuring section | 0695 0574 | |||||
VA 570 Flow sensor with integrated 2" measuring section | 0695 0575 | |||||
VA 570 Flow sensor with integrated DN 15 measuring section with weld neck flange | 0695 2570 | |||||
VA 570 Flow sensor with integrated DN 20 measuring section with weld neck flange | 0695 2571 | |||||
VA 570 Flow sensor with integrated DN 25 measuring section with weld neck flange | 0695 2572 | |||||
VA 570 Flow sensor with integrated DN 32 measuring section with weld neck flange | 0695 2573 | |||||
VA 570 Flow sensor with integrated DN 40 measuring section with weld neck flange | 0695 2574 | |||||
VA 570 Flow sensor with integrated DN 50 measuring section with weld neck flange | 0695 2575 | |||||
VA 570 Flow sensor with integrated DN 65 measuring section with weld neck flange | 0695 2576 | |||||
VA 570 Flow sensor with integrated DN 80 measuring section with weld neck flange | 0695 2577 | |||||
Outer thread measuring section: | Bestell-Code | |||||
A2 - NPT outer thread | A2 | |||||
Option display -Lựa chọn hiển thị | ||||||
B1 - with integrated display | B1 | |||||
B2 - without display | B2 | |||||
78 + 80 | Option signal outputs / bus connection: | |||||
C1 - 2x4...20mA analogue output galv. isolated, pulse output RS485 | C1 | |||||
C4 - 1x4…20mA analogue output (not galv. isolated), pulse output, RS 485 (Modbus RTU) | C4 | |||||
C5 - Ethernet-Interface (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU) | C5 | |||||
C7 - 2x4..20mA analogue output passive, pulse outp.RS485 (Mb-RTU) | C7 | |||||
C8 - E8 - M-Bus (Z6955504) | C8 | |||||
C9 - Ethernet-Interface PoE (Power over Ethernet) (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU) | C9 | |||||
Calibration: | ||||||
D1 - no real gas calibration - gas adjustment via gas constant | D1 | |||||
D2 - real gas calibration in the selected gas type | D2 | |||||
Gas type: | ||||||
E1 - compressed air | E1 | |||||
E2 - Nitrogen (N2) | E2 | |||||
E3 - Argon (Ar) | E3 | |||||
E4 - Carbon dioxide (CO2) | E4 | |||||
E5 - Oxygen (O2) | E5 | |||||
E6 - Nitrous oxide (N2O) | E6 | |||||
E7 - Natural gas (NG) | E7 | |||||
E8 - Helium (He) - Real gas calibration required | E8 | |||||
E9 - Propan (C3H8) - Real gas calibration required | E9 | |||||
E10 - Methane (CH4) | E10 | |||||
E11 - Biogas (Methane 50% : CO2 50%) | E11 | |||||
E12 - Hydrogen (H2) - Real gas calibration required | E12 | |||||
E90 - Further gas | E90 | |||||
E91 - Gas mixture | E91 | |||||
Reference conditions: | ||||||
F1 - 20°C, 1000 hPa | F1 | |||||
F2 - 0°C, 1013,25 hPa | F2 | |||||
F3 - 15°C, 981 hPa | F3 | |||||
F4 - 15°C, 1013,25 hPa | F4 | |||||
Maximum pressure: | ||||||
G1 - 16 bar (Standard) | G1 | |||||
G2 - 40 bar (High pressure) - (not for DVGW approval) | G2 | |||||
Surface condition: | ||||||
H1 - Standard version | H1 | |||||
H2 - Special cleaning - oil and grease free (e.g. for oxygen) | H2 | |||||
H3 - LABS free and silicone free version, incl. oil and grease free | H3 | |||||
78 +80 | Accuracy class: | |||||
I1 - ± 1.5% of measured value (standard) | I1 | |||||
I2 - ± 1 % of measured value (precision) | I2 | |||||
Maximum gas temperature at the sensor tip: | ||||||
J1 - up to 120°C gas temperature (only for ATEX - version) | J1 | |||||
J2 - up to 180°C gas temperature (not for ATEX - version) | J2 | |||||
Approvals: | ||||||
K1 - Non-explosive area - no approval | K1 | |||||
K2 - ATEX II 2G Ex d IIC T4 | K2 | |||||
K3 - DVGW approval (for natural gas) | K3 | |||||
R1 - Special measuring range | R1 | |||||
Further accessories: | ||||||
Connection cable for sensors 5 m with open ends | 0553 0108 | |||||
Connection cable for sensors 10 m with open ends | 0553 0109 | |||||
Ethernet connection cable length 5 m, M12 plug x-coded (8 poles) to RJ 45 plug | 0553 2503 | |||||
Ethernet connection cable length 10 m, M12 plug x-coded (8 poles) to RJ 45 plug | 0553 2504 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Additional calibration point volume flow VA5xx serial, freely selectable | 0700 7720 | |||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | |||||
PNG cable screwing - standard | 0553 0552 | |||||
PNG cable screwing – for ATEX | 0553 0551 | |||||
VA 500 - Flow sensor for compressed air and gases | ||||||
Catalogue page 83 | Order no. | |||||
VA 500 flow sensor, with RS 485 interface (Modbus-RTU) with analogue output 4...20mA and pulse output (galvanically separated), standard version (92,7 m/s) | 0695 5001 | |||||
Measuring range: | ||||||
Max-version (185m/s) | Z695 5003 | |||||
High-Speed-Version (224 m/s) | Z695 5002 | |||||
Option display: | ||||||
with integrated display | Z695 5000 | |||||
without display | ||||||
Option signal output / bus connection: | ||||||
Standard | ||||||
Ethernet-Interface for VA500/VA520, FA500 | Z695 5006 | |||||
Ethernet-Interface PoE for VA500/VA520, FA500 | Z695 5007 | |||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Catalogue page 83 | Mounting length / shaft length: | |||||
220 mm | ZSL0220 | |||||
120 mm | ZSL0120 | |||||
160 mm | ZSL0160 | |||||
300 mm | ZSL0300 | |||||
400 mm | ZSL0400 | |||||
500 mm | ZSL0500 | |||||
600 mm | ZSL0600 | |||||
700 mm | ZSL0700 | |||||
Surface condition: | ||||||
Special cleaning - oil and grease free (e.g. for oxygen) | 0699 4005 | |||||
LABS free and silicone free version incl.cleaning oil and grease free | 0699 4007 | |||||
Gas type: | ||||||
Compressed air | ||||||
Nitrogen (N2) | ||||||
Argon (Ar) | ||||||
Carbon dioxide (CO2) | ||||||
Oxygen (O2) | ||||||
Nitrous oxide (N2O) | ||||||
Natural gas (NG) | ||||||
Helium (He) - Real gas calibration required | ||||||
Propane (C3H8) - Real gas calibration required | ||||||
Methane (CH4) | ||||||
Biogas (Methane 50% : CO2 50%) | ||||||
Hydrogen (H2) - Real gas calibration required | ||||||
Further gas | ||||||
Gas mixture | ||||||
Calibration: | ||||||
Real gas calibration in the selected gas type | ||||||
Special measuring range: | ||||||
Special measuring range freely selectable | Z695 4006 | |||||
Accuracy class: | ||||||
± 1 % of measured value (precision) | Z695 5005 | |||||
Further accessories: | ||||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | |||||
Welding neck, L = 35 mm male screw, R1/2",stainless steel 1.4301 | 3300 0006 | |||||
Welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | |||||
Ethernet-connection cable length 5 m, M 12 plug x-coded (8 poles) to RJ45 | 0553 2503 | |||||
Ethernet-connection cable length 10 m, M 12 plug x-coded (8 poles) to RJ45 | 0553 2504 | |||||
83 | Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m |
0553 0106 | ||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m |
0553 0107 | |||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | |||||
Mains units: | ||||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | |||||
External display, chart recorder DS 400 | 0500 4000 | |||||
Calibration and adjustment - Hiệu chuẩn | ||||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
VA 520 - Flow sensor with integrated measuring section - Screw-in thread - cảm biến dòng khí gas |
||||||
Catalogue page 87 | Stainless steel: 1,4301 | Order no. | ||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | |||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | |||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | |||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | |||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | |||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | |||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | |||||
Stainless steel: 1,4571 | ||||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4571 | 0695 1520 | |||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4571 | 0695 1521 | |||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4571 | 0695 1522 | |||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4571 | 0695 1523 | |||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4571 | 0695 1526 | |||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4571 | 0695 1524 | |||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4571 | 0695 1525 | |||||
Outer thread measuring section of VA 520 with stainless steel 1,4571 | ||||||
NPT outer thread | C2 | |||||
Option signal output / bus connection: | ||||||
Standard | ||||||
Ethernet-Interface für VA500/VA520, FA500 | Z6955006 | |||||
Ethernet-Interface PoE für VA500/VA520, FA500 | Z6955007 | |||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Gas type: | ||||||
Compressed air | ||||||
Nitrogen (N2) | ||||||
Argon (Ar) | ||||||
Carbon dioxide (CO2) | ||||||
Oxygen (O2) | ||||||
Nitrous oxide (N2O) | ||||||
Natural gas (NG) | ||||||
Helium (He) - Real gas calibration required | ||||||
Propane (C3H8) - Real gas calibration required | ||||||
Methane (CH4) | ||||||
Biogas (Methane 50% : CO2 50%) | ||||||
Hydrogen (H2) - Real gas calibration required | ||||||
Further gas | ||||||
Gas mixture | ||||||
Calibration: | ||||||
Real gas calibration in the selected gas type | ||||||
Catalogue page 87 | Maximum pressure: | |||||
40 bar (High-pressure) | Z695 0411 | |||||
Surface condition: | ||||||
Special cleaning - oil and grease free (e.g. for oxygen) | 0699 4005 | |||||
LABS free and silicone free version incl.cleaning oil and grease free | 0699 4007 | |||||
Special measuring range: | ||||||
Special measuring range freely selectable | Z695 4006 | |||||
Accuracy class: | ||||||
± 1 % of measured value (precision) | Z695 5005 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | |||||
Ethernet-connection cable length 5 m, M 12 plug x-coded (8 poles) RJ 45 plug | 0553 2503 | |||||
Ethernet-connection cable length 10 m, M 12 plug x-coded (8 poles) RJ 45 plug | 0553 2504 | |||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m | 0553 0106 | |||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m | 0553 0107 | |||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | |||||
Closing cap for measuring section in aluminium | 0190 0001 | |||||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | |||||
Mains units: | ||||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | |||||
External display, chart recorder DS 400 | 0500 4000 | |||||
Calibration and adjustment: | ||||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
VA 520 - Flow sensor with integrated measuring section - weld neck flange | ||||||
Catalogue page 89 | Order no. | |||||
VA520 Flow meter with integrated DN 15 measuring section with flange | 0695 2521 | |||||
VA520 Flow meter with integrated DN 20 measuring section with flange | 0695 2522 | |||||
VA520 Flow meter with integrated DN 25 measuring section with flange | 0695 2523 | |||||
VA520 Flow meter with integrated DN 32 measuring section with flange | 0695 2526 | |||||
VA520 Flow meter with integrated DN 40 measuring section with flange | 0695 2524 | |||||
VA520 Flow meter with integrated DN 50 measuring section with flange | 0695 2525 | |||||
VA520 Flow meter with integrated DN 65 measuring section with flange | 0695 2527 | |||||
VA520 Flow meter with integrated DN 80 measuring section with flange | 0695 2528 | |||||
Option signal output / bus connection: | ||||||
Standard | ||||||
Ethernet-Interface for VA500/VA520, FA500 | Z695 5006 | |||||
Ethernet-Interface PoE for VA500/VA520, FA500 | Z695 5007 | |||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Gas type: | ||||||
Compressed air | ||||||
Nitrogen (N2) | ||||||
Argon (Ar) | ||||||
Carbon dioxide (CO2) | ||||||
Oxygen (O2) | ||||||
Nitrous oxide (N2O) | ||||||
Natural gas (NG) | ||||||
Helium (He) - Real gas calibration required | ||||||
Propane (C3H8) - Real gas calibration required | ||||||
Methane (CH4) | ||||||
Biogas (Methane 50% : CO2 50%) | ||||||
Hydrogen (H2) - Real gas calibration required | ||||||
Further gas | ||||||
Gas mixture | ||||||
Calibration: | ||||||
Real gas calibration in the selected gas type | ||||||
Maximum pressure: | ||||||
40 bar (High-pressure) | Z695 0411 | |||||
Surface condition: | ||||||
Special cleaning - oil and grease free (e.g. for oxygen) | 0699 4005 | |||||
LABS free and silicone free version incl.cleaning oil and grease free | 0699 4007 | |||||
Special measuring range: | ||||||
Special measuring range freely selectable | Z695 4006 | |||||
Catalogue page 89 | Accuracy class: | |||||
± 1 % of measured value (precision) | Z695 5005 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | |||||
Ethernet-connection cable length 5 m, M 12 plug x-coded (8 poles) to RJ 45 | 0553 2503 | |||||
Ethernet-connection cable length 10 m, M 12 plug x-coded (8 poles) to RJ 45 | 0553 2504 | |||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m |
0553 0106 | |||||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m | 0553 0107 | |||||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | |||||
Closing cap for measuring section in aluminium | 0190 0001 | |||||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 20000823 | |||||
Mains units: | ||||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | |||||
External display, chart recorder DS 400 | 0500 4000 | |||||
Calibration and adjustment: | ||||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
Flow measurement DS 400 for compressed air and gases | ||||||
Catalogue page 90 | Order no. | |||||
Flow station DS 400 for installation into existing pipelines consisting of: | 0601 4006 | |||||
consisting of: | ||||||
Chart recorder DS 400 and flow sensor VA 500 in standard version (92,7 m/s), Sensor length 220 mm |
||||||
Options for chart recorder DS 400: | ||||||
Integrated data logger for 100 million measured values | Z500 4002 | |||||
Integrated Ethernet and RS 485 interface | Z500 4004 | |||||
External Gateway PROFIBUS for RS 485 interface connection | Z500 3008 | |||||
External Gateway PROFINET for RS 485 interface connection | Z500 3009 | |||||
2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors etc.) | Z500 4001 | |||||
2 additional sensor inputs for digital sensors (SDI/Modbus) | Z500 4003 | |||||
Integrated webserver | Z500 4005 | |||||
Option “mathematics calculat. function” for 4 freely selectable “virtual” channels | Z500 4007 | |||||
Option "Totalizer function for analogue signals" | Z500 4006 | |||||
VA 500 Verbrauchssensor, mit RS 485 (Modbus-RTU) Schnittstelle, mit Analogausgang 4...20mA und Impulsausgang (galvanisch getrennt) | 0695 5001 | |||||
Max. Version (185 m/s) | Z695 5003 | |||||
High Speed Version (224 m/s) | Z695 5002 | |||||
Display | Z695 5000 | |||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Sensor length 120 mm | ZSL 0120 | |||||
Sensor length 160 mm | ZSL 0160 | |||||
Sensor length 220 mm | ZSL 0220 | |||||
Sensor length 300 mm | ZSL 0300 | |||||
Sensor length 400 mm | ZSL 0400 | |||||
Sensor length 500 mm | ZSL 0500 | |||||
Sensor length 600 mm | ZSL 0600 | |||||
Sensor length 700 mm | ZSL 0700 | |||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | |||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | |||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | |||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
Oil and fat free, special cleaning | 0699 4005 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
Further accessories: | ||||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | |||||
Calibration and adjustment: | ||||||
5 point precision calibration including ISO certificate | 3200 0001 | |||||
DS 400 - Chart recorder | ||||||
Catalogue page 92 | Order no. | |||||
Product | sensor- input 1+2 |
sensor- input 3+4 |
||||
Chart recorder DS400 - with 3.5“ graphic display – easy operation with touch screen | digital | ---------- | 0500 4000 D | |||
digital | digital | 0500 4000 DD | ||||
digital | analogue | 0500 4000 DA | ||||
analogue | ---------- | 0500 4000 A | ||||
analogue | analogue | 0500 4000 AA | ||||
Options: | ||||||
Integrated data logger for 100 Mio. measured values | Z500 4002 | |||||
Integrated Ethernet- and RS 485 interface | Z500 4004 | |||||
2 additional sensor inputs for analogue sensors (like: pressure, temperautre sensors ...) | Z500 4001 | |||||
2 additional sensor inputs for digital sensors (SDI/Modbus) | Z500 4003 | |||||
External Gateway PROFIBUS for RS 485 interface connection | Z500 3008 | |||||
External Gateway PROFINET for RS 485 interface connection | Z500 3009 | |||||
Integrated webserver | Z500 4005 | |||||
"Mathematics calculation function" for 4 freely selectable channels, (virtual channels): addition, subtraction, division, multiplication |
Z500 4007 | |||||
"Totalizer function for analogue signals" | Z500 4006 | |||||
Further accessories: | ||||||
CS Soft Basic - data evaluation in graphic and table form, reading out of the measured data via USB or Ethernet |
0554 7040 | |||||
CS Soft Network - Database Client/Server Solution (up to 5 DS 400) - 0554.7041 database (MySQL) to Server - data evaluation via Client-Software |
0554 7041 | |||||
CS Soft Network - Database Client/Server Solution (up to 10 DS 400) - 0554.7042 database (MySQL) to Server - data evaluation via Client-Software |
0554 7042 | |||||
CS Soft Network - Database Client/Server Solution (up to 20 DS 400) - 0554.7043 database (MySQL) to Server - data evaluation via Client-Software |
0554 7043 | |||||
CS Soft Network - Database Client/Server Solution (> 20 DS 400) - 0554.7044 database (MySQL) to Server - data evaluation via Client-Software |
0554 7044 | |||||
Software Support / h | 9999 9998 | |||||
Ready for plug in and parametrization | 0990 0010 | |||||
Everything ready for plug in | 0990 0011 | |||||
Flow sensor VA 500 | ||||||
Catalogue page 93 | Order no. | |||||
VA 500 flow sensor, with RS 485 interface (Modbus-RTU), with analogue output 4...20mA and pulse output (galvanically separated) | 0695 5001 | |||||
Max. Version (185 m/s) | Z695 5003 | |||||
HighSpeed version (224 m/s) | Z695 5002 | |||||
Display | Z695 5000 | |||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Sensor length 120 mm | ZSL 0120 | |||||
Sensor length 160 mm | ZSL 0160 | |||||
Sensor length 220 mm | ZSL 0220 | |||||
Sensor length 300 mm | ZSL 0300 | |||||
Sensor length 400 mm | ZSL 0400 | |||||
Sensor length 500 mm | ZSL 0500 | |||||
Sensor length 600 mm | ZSL 0600 | |||||
Sensor length 700 mm | ZSL 0700 | |||||
Ball valve I/I G 1/2" stainless steel | 3300 0002 | |||||
welding neck, L = 35 mm, male screw, R1/2",stainless steel 1.4301 | 3300 0006 | |||||
welding neck, L= 35 mm, male screw, R1/2",stainless steel 1.44571 | 3300 0007 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 20000823 | |||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
Oil and fat free, special cleaning | 0699 4005 | |||||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
Flow sensor VA 520 with integrated measuring section - Cảm biến dòng khí gas | ||||||
Catalogue page 93 | Order no. | |||||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | |||||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | |||||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | |||||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | |||||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | |||||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | |||||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | |||||
Option: | ||||||
M-Bus (pulse output not available) | Z695 5004 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | |||||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | |||||
Option: special cleaning | 0699 4005 | |||||
5 point precision calibration with ISO certificate | 3200 0001 | |||||
93 | Real gas calibration | 3200 0015 | ||||
Real gas calibration for mixed gases | on request | |||||
Further accessories: | ||||||
Closing cap for measuring section in aluminium | 0190 0001 | |||||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | |||||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | |||||
Flow measurment VA 500/ VA 520 for below gases - cảm biến dòng khí gas | ||||||
Order no. | ||||||
Oxygen (O2), carbon dioxide (CO2), nitrogen (N2), argon (Ar), nitrous oxide (N2O), natural gas, helium (He), hydrogen (H2), propane, methane | on request | |||||
Dew point sensors FA 510 - cảm biến điểm sương | ||||||
93 | Order no. | |||||
FA 510 dew point sensor for desiccant driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0510 | |||||
FA 510 dew point sensor for refrigertation driers incl. inspection certificate, 4…20 mA output signal (3-wire connection) and Modbus-RTU interface | 0699 0512 | |||||
Measuring chamber with inner threat G1/2" and mounted male coupling DN 7,2 for quick-lock coupling |
0699 3390 | |||||
More measuring chambers please see on catalogue page 60 | ||||||
Connection cables for VA/FA sensors - cáp kết nối | ||||||
93 | Order no. | |||||
Connection cable for VA/FA, 5 m with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m with M12 plug | 0553 0105 | |||||
Connection cable for VA/FA, 20 m with M12 plug | 0553 0120 | |||||
Pressure sensors - cảm biến áp suất | ||||||
Catalogue page 93 | Order no. | |||||
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale | 0694 1886 | |||||
Precision pressure sensor CS 16, accuracy ± 0.5 % | 0694 3555 | |||||
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale | 0694 0356 | |||||
Precision Pressure sensor CS 40, accuracy ± 0.5 % | 0694 3930 | |||||
Standard pressure sensor CS 1.6 absolute, 0...1.6 bar abs.,± 0,5 % accuracy of full scale | 0694 3550 | |||||
Standard pressure sensor CS 10 (0…10 bar), ± 1 % accuracy of full scale | 0694 3556 | |||||
Precision pressure sensor CS 10 (0…10 bar), ± 0,5 % accuracy of full scale | 0694 3554 | |||||
Precision pressure sensorCS 100, 0...100 bar, ± 0,5 % accuracy of full scale | 0694 3557 | |||||
Precision pressure sensor CS 250, 0...250 bar, ± 0,5 % accuracy of full scale | 0694 3558 | |||||
Precision pressure sensor CS 400, 0...400 bar, ± 0,5 % accuracy of full scale | 0694 3559 | |||||
Precision pressure sensor CS, -1...+15 bar, ± 0.5 % accuracy of full scale | 0694 3553 | |||||
Precision differential pressure sensor CS 0…400 mbar differential pressure, accuracy: 0.075 % of full scale, static pressure max. 40 bar |
0694 3560 | |||||
Precision pressure sensor CS (0..0.6 bar) accuracy < 0.5 % | 0694 3549 | |||||
Calibration of pressure sensor 5 points between 0 and 10/16 bar | 3200 0004 | |||||
Precision differential pressure sensor for further measuring, ranges, e. g. 0…75 mbar, 0…2 bar, 0…8 bar, 0…21 bar, 0…70 bar, 0…200 bar, 0…420 bar |
on request | |||||
Temperature sensors - cảm biến nhiệt | ||||||
93 | Order no. | |||||
Screw-in temperature probe PT 100 class A, length: 300 mm, d=6mm, with integrated transducer 4…20 mA = -50°C…+500°C (2-wire) |
0604 0201 | |||||
Outdoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0203 | |||||
Indoor temperature probe, PT 100 class B (2-wire) in wall housing (82x55x33 mm), temperature range: -50°C to +80°C |
0604 0204 | |||||
Temperature probe PT 100 class A (4-wire) with cable, length: 300 mm, d=6 mm, -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0205 | |||||
Temperature probe PT 100 class A (4-wire) with cable, length: 100 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0206 | |||||
Temperature probe PT 100 class A (4-wire) with cable, length: 200 mm, d=6 -70°C to +260°C, 5 m connection cable (PFA) with open ends |
0604 0207 | |||||
Surface temperature probe, magnetic, magnet dimensions 39x26x25 mm, PT 100 class B (2-wire), -30 to +180°C, 5 m connection cable (PFA) with open ends |
0604 0208 | |||||
Clamp screwing 6mm; G 1/2" PTFE clamp ring pressure tight up 10 bar material: stainless steel, temperature range: max. +260°C |
0554 0200 | |||||
Clamp screwing 6mm; G 1/2" stainless steel clamp ring pressure tight up to 16 bar, material: stainless steel, temperature range: max. +260°C |
0554 0201 | |||||
Connection cables for pressure/temperature sensors - cáp kết nối | ||||||
93 | Order no. | |||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | |||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | |||||
Clamp-on meters - đồng hồ đo khí dạng gắn ngoài | ||||||
93 | Order no. | |||||
Clamp-on ammeter 0...400 A TRMS incl. 3 m connection cable with open ends | 0554 0510 | |||||
Clamp-on ammeter 0…1000 A RMS, 4…20 mA = 0…1000 A, 10-30 VDC, 3 m connection cable with open ends | 0554 0518 | |||||
Calibration certificate for clamp-on ammeters, 5 calibration points | 0554 3333 | |||||
CS ENERIUM 30 Current/effective power meter for panel mounting | ||||||
Catalogue page 93 | Order no. | |||||
CS ENERIUM 30 Current/effective power meter for panel mounting, with RS 485 interface |
0554 5355 | |||||
Current transformer 100/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5344 | |||||
Current transformer 200/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 21 mm) |
0554 5345 | |||||
Current transformer 300/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5346 | |||||
Current transformer 500/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5347 | |||||
Current transformer 600/5 A connectable to current/effective power meter for panel mounting (for cabels up to Ø 22 mm) |
0554 5348 | |||||
Current transformer 1000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 65 x 32 mm) |
0554 5349 | |||||
Current transformer 2000/5 A connectable to current/effective power meter for panel mounting (for current bar up to 127 x 38 mm) |
0554 5350 | |||||
Connection cable CS ENERIUM 30 | ||||||
Connection cable for sensors 5 m, with open ends | 0553 0108 | |||||
Connection cable for sensors 10 m, with open ends | 0553 0109 | |||||
Connection cable variable length, open ends on both sides | 0553 0126 | |||||
VA 409 Flow direction switch for compressed air systems- công tắc lưu lượng cho khí nén | ||||||
98 | Order no. | |||||
Flow direction switch VA 409 | 0695 0409 | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
Connection cable VA/FA Series 400, 5 m with M12 plug | 0553 0104 | |||||
Connection cable VA/FA Series 400, 10 m with M12 plug | 0553 0105 | |||||
Measuring sections of stainless steel 1.4301 incl. ball valve | ||||||
Catalogue page 100 | Up to DN 65 (G2 1/2”) with external thread, from DN 80 with weld neck flange according to DIN 2633 | Order no. | ||||
Measuring section G 1/2” 21.3 x 2.6 mm 500 mm | 4000 0015 | |||||
Measuring section G 3/4” 26.9 x 2.6 mm 600 mm | 4000 0020 | |||||
Measuring section G 1” 33.7 x 3.2 mm 750 mm | 4000 0025 | |||||
Measuring section G 1 1/4” 42.4 x 3.2 mm 900 mm | 4000 0032 | |||||
Measuring section G 1 1/2” 48.3 x 3.2 mm 1000 mm | 4000 0040 | |||||
Measuring section G 2” 60.3 x 3.6 mm 1250 mm | 4000 0050 | |||||
Measuring section G 2 1/2” 76.1 x 3.6 mm 1500 mm | 4000 0065 | |||||
Measuring section DN 80/88.9 88.9 x 2.0 mm 1850 mm | 4000 0080 | |||||
Measuring section DN 100/114.3 114.3 x 2.0 mm 2104 mm | 4000 0100 | |||||
Measuring section DN 125/139.7 139.7 x 3.0 mm 2860 mm | 4000 0125 | |||||
Measuring section DN 150/168,3 168,3 x 3,0 mm 3110 mm | 4000 0150 | |||||
Accessories: | ||||||
Drilling jig incl. drill (Ø 13 mm) | 0530 1108 | |||||
High-pressure protection f. installation from 10 to 50 bar (for VA400/500) | 0530 1105 | |||||
High-pressure protection f. installation from 10 to 100 bar (for VA 550) | 0530 1115 | |||||
High-pressure protection f. installation from 10 to 16 bar DVGW (for VA 550) | 0530 1116 | |||||
Drilling clamp incl. ball valve 1/2" | ||||||
Catalogue page 101 | Order no. | |||||
Spot drilling collar for pipe diameter 032 - 036 mm, length: 100 mm | 0500 0446 | |||||
Spot drilling collar for pipe diameter 036 - 040 mm, length: 100 mm | 0500 0448 | |||||
Spot drilling collar for pipe diameter 040 - 044 mm, length: 150 mm | 0500 0449 | |||||
Spot drilling collar for pipe diameter 044 - 051 mm, length: 200 mm | 0500 0610 | |||||
Spot drilling collar for pipe diameter 048 - 055 mm, length: 200 mm | 0500 0611 | |||||
Spot drilling collar for pipe diameter 052 - 059 mm, length: 200 mm | 0500 0612 | |||||
Spot drilling collar for pipe diameter 057 - 064 mm, length: 200 mm | 0500 0613 | |||||
Spot drilling collar for pipe diameter 063 - 070 mm, length: 200 mm | 0500 0614 | |||||
Spot drilling collar for pipe diameter 070 - 077 mm, length: 200 mm | 0500 0615 | |||||
Spot drilling collar for pipe diameter 075 - 083 mm, length: 200 mm | 0500 0616 | |||||
Spot drilling collar for pipe diameter 082 - 090 mm, length: 200 mm | 0500 0617 | |||||
Spot drilling collar for pipe diameter 087 - 097 mm, length: 200 mm | 0500 0618 | |||||
Spot drilling collar for pipe diameter 095 - 104 mm, length: 200 mm | 0500 0619 | |||||
Spot drilling collar for pipe diameter 102 - 112 mm, length: 200 mm | 0500 0620 | |||||
Spot drilling collar for pipe diameter 108 - 118 mm, length: 200 mm | 0500 0621 | |||||
Spot drilling collar for pipe diameter 118 - 128 mm, length: 200 mm | 0500 0622 | |||||
101 | Spot drilling collar for pipe diameter 125 - 135 mm, length: 200 mm | 0500 0623 | ||||
Spot drilling collar for pipe diameter 133 - 144 mm, length: 200 mm | 0500 0624 | |||||
Spot drilling collar for pipe diameter 145 - 155 mm, length: 250 mm | 0500 0625 | |||||
Spot drilling collar for pipe diameter 151 - 161 mm, length: 250 mm | 0500 0626 | |||||
Spot drilling collar for pipe diameter 159 - 170 mm, length: 250 mm | 0500 0627 | |||||
Spot drilling collar for pipe diameter 168 - 180 mm, length: 250 mm | 0500 0628 | |||||
Spot drilling collar for pipe diameter 180 - 191 mm, length: 250 mm | 0500 0629 | |||||
Spot drilling collar for pipe diameter 193 - 203 mm, length: 300 mm | 0500 0630 | |||||
Spot drilling collar for pipe diameter 200 - 210 mm, length: 300 mm | 0500 0631 | |||||
Spot drilling collar for pipe diameter 209 - 220 mm, length: 300 mm | 0500 0632 | |||||
Ball valve G 1/2" I - R 1/2"O | 0500 3009 | |||||
Thickness meter CS 0495 - Thiết bị đo độ dày | ||||||
101 | Order no. | |||||
Thickness meter CS 0495, incl. case and calibration block | 0560 0495 | |||||
Re-calibration | ||||||
103 | Order no. | |||||
Re-calibration and 5 point precision alignment of consumption sensor with ISO certificate | 0695 3333 | |||||
Real gas calibration | 3200 0015 | |||||
Real gas calibration for mixed gases | on request | |||||
OIL-Check & Particle counter PC 400 - Máy đếm và kiểm tra lượng dầu PC 400 | ||||||
Stationary solution DS 500 - Giải pháp tại chỗ DS 500 | Order no. | |||||
DS 500 – intelligent chart recorder in basic version (4 sensor inputs) | 0500 5000 | |||||
CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places | 0554 8040 | |||||
Residual oil measurement: OIL-Check 400 – residual oil content measurement of the vaporous residual oil content from 0.001…2,5 mg/m³, 3…16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0…10 Volt for connection to an external chart recorder. |
0699 0070 | |||||
Sampling system OIL-Check 400: Sampling system consisting of ½“ ball valve (oil- and grease-free), 1 m stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free) |
Z699 0075 | |||||
Alternative: Portable sampling system consisting of 2 m PTFE hose, quick-lock coupling (oil- and grease-free) |
Z699 0074 | |||||
Options for systems > 16 bar: Pressure reducer (oil- and grease-free), input pressure max. 300 bar, output pressure up to 10 bar |
Z699 0076 | |||||
Connection cable for probes, 5 m with open ends | 0553 0108 | |||||
PC 400 particle counter up to 0.1 µm for compressed air and gases, incl. pressure reducer/sampling hose/ calibration certificate, Modbus-RTU interface | 0699 0040 | |||||
Connection cable for probes, 5 m with open ends | 0553 0108 | |||||
FA 510 dew point sensor for adsorption driers -80°...20°Ctd incl. inspection certificate, 4...20 mA analogue output (3-wire technology) and Modbus-RTU interface |
0699 0510 | |||||
Standard measuring chamber up to 16 bar | 0699 3390 | |||||
Connection cable for VA/FA Series, 5 m | 0553 0104 | |||||
Mobile solution with DS 500 mobile, OIL-Check 400, PC 400, FA 510 - Giải pháp di động | Bestell-Nr. | |||||
DS 500 mobile - intelligent chart recorder with 4 sensors inputs | 0500 5012 | |||||
CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places | 0554 8040 | |||||
Residual oil measurement: OIL-Check 400 – residual oil measurement of the vaporous residual oil content from 0.001…2.5 mg/m³, 3…16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0…10 Volt for connection to external chart recorders |
0699 0070 | |||||
Mobile transport trolley including roles (outer dimensions: 1.0 x 0.7 x 0.35 m (W x H x D) with firmly mounted components of OIL-Check 400, PC 400, FA 510 |
0554 6017 | |||||
Mobile sampling system consisting of 2 m PTFE hose, quick lock coupling (oil- and grease-free) | Z699 0074 | |||||
Connection cable for pressure, temperature, third party sensors to portable devices, ODU / open ends, 5 m |
0553 0501 | |||||
PC 400 particle counter up to 0.1 µm for compressed air and gases, incl. pressure reducer/sampling hose, calibration certificate, Modbus-RTU interface |
0699 0040 | |||||
Connection cable for probes, 5 m with open ends | 0553 0501 | |||||
FA 510 dew point sensor, -80°...+20°Ctd, incl. mobile measuring chamber and 5 m connection cable to portable devices | 0699 1510 | |||||
OIL-Check 400 – stationary solution with DS 400 - Giải pháp kiểm tra lượng dầu tại chỗ DS 400 |
Order no. | |||||
OIL-Check 400 – residual oil content measurement of the vaporous residual oil content from 0.001…2,5 mg/m³, 3…16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration, without integrated display, with analogue output 0…10 Volt for connection to an external chart recorder | 0699 0070 | |||||
Option: DS 400 chart recorder integrated in the OIL-Check 400 | Z699 0071 | |||||
Sampling OIL-Check 400: kiểm tra mẫu dầu DS-400 Sampling system consisting of ½“ ball valve (oil- and grease-free), 1 m stainless steel tube 6x1 mm (oil- and grease-free), clamp screwing (oil- and grease-free) |
Z699 0075 | |||||
Alternative: Portable sampling system consisting of 2 m Teflon hose, quick-lock coupling (oil- amnd gas free) |
Z699 0074 | |||||
Options for systems > 16 bar: Pressure reducer (oil- and grease-free), input pressure max. 300 bar, output pressure up to 10 bar |
Z699 0076 | |||||
Optionen for DS 400: | Bestell-Nr. | |||||
Option: Integrated data logger for 100 million measured values | Z500 4002 | |||||
Option: Integrated Ethernet and RS 485 interface | Z500 4004 | |||||
Option: Integrated Webserver | Z500 4005 | |||||
Option: 2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors and so on) | Z500 4001 | |||||
CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places | 0554 8040 | |||||
OIL-Check 400 portable solution with handle - Thiết bị kiểm tra dầu dạng cầm tay series 400 |
Order no. | |||||
OIL-Check 400 – residual oil measurement of the vaporous residual oil content from 0.001…2.5 mg/m³, 3…16 bar. Highly precise PID sensor, integrated mini catalyst for zero point calibration. Without integrated display, with alarm output 0…10 Volt for connection to external chart recorder | 0699 0070 | |||||
Option: DS 400 chart recorder integrated in the OIL-Check 400 | Z699 0071 | |||||
Option: Handle and pedestal for mobile use of the OIL-Check 400 | Z699 0072 | |||||
Alternative: | ||||||
Option: Flight case for OIL-Check 400 | Z699 0073 | |||||
Option: Mobile sampling system consisting of 2 m PTFE hose, quick lock coupling (oil- and grease-free) | Z699 0074 | |||||
Optionen for DS 400: | ||||||
Option: Integrated data logger for 100 million measured values | Z500 4002 | |||||
Option: Integrated Ethernet and RS 485 interface | Z500 4004 | |||||
Option: Integrated Webserver | Z500 4005 | |||||
Option: 2 additional sensor inputs for analogue sensors (pressure sensors, temperature sensors and so on) | Z500 4001 | |||||
CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places | 0554 8040 | |||||
Descreption | Order no. | |||||
Replacement unit OIL-Check for the period of re-calibration | 0699 3910 | |||||
Replacement unit OIL-Check incl. DS 400 for the period of re-calibration | 0699 3920 | |||||
Re-calibration OIL-Check incl. Certificate | 0699 3301 | |||||
Re-calibration and maintenance OIL-Check incl. certificate, rate 1 for up to 8760 hours of operatio | 0699 3302 | |||||
Re-calibration and maintenance OIL-Check incl. certificate, rate 2 for over 8760 hours of operation | 0699 3303 | |||||
LD 500/510 leak detector - Cảm biến phát hiện rò rỉ khí LC500/510 | ||||||
Katalogseite 114-117 | order-no. | |||||
Set LD 500 | 0601 0105 | |||||
consisting of: | ||||||
LD 500 leak detector with acoustic trumpet, and integrated camera, 100 leak tags for marking the leakages on site |
0560 0105 | |||||
Transportation case | 0554 0106 | |||||
Sound-proof headset | 0554 0104 | |||||
Focus tube with focus tip | 0530 0104 | |||||
AC adapter plug | 0554 0009 | |||||
Helix cable for connecting the ultrasonic sound sensor | 02000 1402 | |||||
Set LD 510 | 0601 0106 | |||||
consisting of: | ||||||
LD 510 leak detector incl. acoustic trumpet, with integrated camera and additional input forexternal sensors, 100 leak tags for marking the leakages on site | 0560 0106 | |||||
Transportation case | 0554 0106 | |||||
Sound-proof headset | 0554 0104 | |||||
Focus tube with focus tip | 0530 0104 | |||||
AC adapter plug | 0554 0009 | |||||
Helix cable for connecting the ultrasonic sound sensor | 02000 1402 | |||||
Equipment: | ||||||
CS Leak Reporter – for detailed ISO 50001 reports. Gives an illustrated survey of the found leakages and their possible savings. Measures for elimination including status display can be defined for every leakage. |
0554 0105 | |||||
Gooseneck for leakage detection at sites which are difficult to access | 0530 0105 | |||||
Parabolic mirror for leak detection at long distances | 0530 0106 | |||||
Ultrasonic tone generator for leak testing | 0554 0103 | |||||
500 leak tags for marking the leakages on site | 0530 0107 | |||||
Calibration: | ||||||
Recalibration LD 500/LD510 inclusive certificate | 0560 3333 | |||||
Further sensors / accessories for connection to LD 510: | ||||||
FA 510 dew point sensor for mobile devices, -80…+20°Ctd, incl. mobile measuring chamber, 5m connection cable and perforated protection cap |
0699 1510 | |||||
Flow sensor VA 500, Max version (185 m/s) sensor length 220 mm, incl. 5 m connection cable |
0695 1124 | |||||
Standard pressure sensor CS 16, 0…16 bar, ± 1 % accuracy of f. s | 0694 1886 | |||||
Differential pressure sensor 1.6 bar diff. | 0694 3561 | |||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU /open ends, 5 m | 0553 0501 | |||||
CS Basic 2018 - data evaluation in graphic and table form - reading out of the measured data via USB Stick or Ethernet. License for 2 computers | 0554 8040 | |||||
LD 400 Leak detector - Cảm biến phát hiện rò rỉ khí LD400 | ||||||
118-119 | Order no. | |||||
Set LD 400 leak detector | 0601 0104 | |||||
consisting of: | ||||||
LD 400 Leak detector | 0560 0104 | |||||
Transport case | 0554 0106 | |||||
Sound-proof headset | 0554 0104 | |||||
Focus tube with focus tip | 0530 0104 | |||||
Battery charger | 0554 0009 | |||||
Acoustictrumpet | 0530 0109 | |||||
Accessory, not included in the set: | ||||||
Ultrasonic tone generator | 0554 0103 | |||||
Affordable differential pressure sensor for testing filter performance - cảm biến áp suất | ||||||
120-121 | Order no. | |||||
Differential Pressure Sensor 1.6 bar diff | 0694 3561 | |||||
Connection cables: | ||||||
Connection cable for sensors 5 m with open ends | 0553 0108 | |||||
Connection cable for sensors 10 m with open ends | 0553 0109 | |||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m |
0553 0501 | |||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 10 m |
0553 0502 | |||||
For mobile measurements in a set with PI 500: | ||||||
PI 500 portable measuring instrument with integrated data logger | 0560 0511 | |||||
Differential Pressure Sensor 1.6 bar diff | 0694 3561 | |||||
Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m | 0553 0501 | |||||
For stationary measurements in a set with DS 52: | ||||||
DS 52 LED display in wall housing | 0500 0009 | |||||
Differential Pressure Sensor 1.6 bar diff | 0694 3561 | |||||
Connection cable for sensors 5 m with open ends | 0553 0108 | |||||
DS 52 – Digital process meter - máy đo kỹ thuật số | ||||||
122 | Order no. | |||||
DS 52 LED display in wall housing | 0500 0009 | |||||
Options: | ||||||
Supply 24 VDC instead of 230 VAC | Z500 0001 | |||||
Supply 110 VAC instead 230 VAC | Z500 0002 | |||||
Alarm unit mounted at wall housing | Z500 0003 | |||||
Alarm unit for external mounting | Z500 0004 | |||||
DS 52 – all-in one set for pressure monitoring /alerting, consisting of DS 52 LED display and pressure sensor 0...16 bar |
on request | |||||
DS 52 – all-in one set for temperature monitoring /alerting, consisting of DS 52 LED display and screw-in temperature probe -50...+500°C |
on request | |||||
DS 51 – Digital panel meter | ||||||
123 | Order no. | |||||
DS 51 – digital meter for panel mounting, supply 230 VAC, sensor input for 0(4)...20 mA signal, 2 alarm relays |
0500 0006 | |||||
Options: | ||||||
Supply 24 VDC instead of 230 VAC | Z500 0001 | |||||
Supply 110 VAC instead of 230 VAC | Z500 0002 | |||||
Re-Calibration and service (not discountable) | ||||||
64 + 103 | Order no. | |||||
Re-calibration and precision alignment | 0699 3333 | |||||
Additional calibration point pressure dew point | 0700 7710 | |||||
Re-calibration and 5 point precision alignment of flow sensor with ISO certificate | 0695 3333 | |||||
Replacement unit for the period of re-calibration | 0699 3900 | |||||
Dew point meter in exchange with calibration certificate from our instrument pool | 0699 3990 | |||||
Flow sensor with calibration certificate from our instrument pool | 0695 3990 | |||||
Re- calibration Oil Check with Certificate | 0699 3301 | |||||
Re- calibration and maintenance Oil Check, with Certificate, rate 1 up to 8760 hours of operation | 0699 3302 | |||||
Re- calibration and maintenance Oil Check, with Certificate, rate 2 over 8760 hours of operation | 0699 3303 | |||||
Replacement unit OIL-Check for the period of re-calibration | 0699 3910 | |||||
Replacement unit OIL-Check with DS 400 for the period of re-calibration | 0699 3920 | |||||
Re- calibration particle counter PC 400 with Certificate | 0699 3304 | |||||
Products not included in the catalogue - Danh mục sản phẩm không bao gồm trong catalogue | ||||||
FA 540 dew point sensor with same pinning at M12 plug as FA 410 |
||||||
FA 540 dew point sensor for desiccant driers -80...20°Ctd incl. inspection certificate, 4…20 mA output signal (3-wire connection) |
0699 0540 | |||||
FA 540 dew point sensor for refrigeration driers -20...50°Ctd incl. inspection certificate, 4…20 mA output signal (3-wire connection) |
0699 0542 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Options for FA 540: | ||||||
Option max. pressure FA5xx 350 bar | Z699 0515 | |||||
Option special scaling FA5xx, 4…20 mA=__ … __ g/m³, ppm etc. | Z699 0514 | |||||
Option connection thread FA5xx, 5/8" UNF | Z699 0511 | |||||
Option surface condition FA5xx, free of oil & grease | Z699 0517 | |||||
Additional accessories: | ||||||
Standard measuring chamber up to 16 bar | 0699 3390 | |||||
High pressure measuring chamber up to 350 bar | 0699 3590 | |||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
CS Service software incl. PC connection set for FA540/545 sensors | 0554 2008 | |||||
Calibration and adjustment: | ||||||
Precision calibration at 3°Ctd including ISO certificate | 0699 3396 | |||||
Additional calibration point, freely selectable | 0700 7710 | |||||
FA 545 dew point sensor with same pinning at M12 plug as FA 415 - cảm biến điểm sương FA 545 |
||||||
FA 545 dew point sensor for refrigeration driers -20...50°Ctd incl. inspection certificate, 4…20 mA output signal (2-wire connection) |
0699 0547 | |||||
FA 545 dew point sensor for desiccant driers -80...20°Ctd incl. inspection certificate, 4…20 mA output signal (2-wire connection) |
0699 0545 | |||||
Connection cables: | ||||||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | |||||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | |||||
Options for FA 545: | ||||||
Option max. pressure FA5xx 350 bar | Z699 0515 | |||||
Option special scaling FA5xx, 4…20 mA=__ … __ g/m³, ppm etc. | Z699 0514 | |||||
Option connection thread FA5xx, 5/8" UNF | Z699 0511 | |||||
Option surface condition FA5xx, free of oil & grease | Z699 0517 | |||||
Additional accessories: | ||||||
Standard measuring chamber up to 16 bar | 0699 3390 | |||||
High pressure measuring chamber up to 350 bar | 0699 3590 | |||||
Measuring chamber,stainless steel 1.4305, for dew point measurement in gases/air, up to 350 bar gas inlet: G ¼” inner thread, gas outlet: G ¼“ inner thread, sensor connection: G ½” inner thread | 0699 3290 | |||||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | |||||
CS Service software incl. PC connection set for FA540/545 sensors | 0554 2008 | |||||
Calibration and adjustment: | ||||||
Precision calibration at 3°Ctd including ISO certificate | 0699 3396 | |||||
Additional calibration point, freely selectable | 0700 7710 |